Avaya Nortel Communication Server 1000 Reference page 183

Circuit card reference
Hide thumbs Also See for Nortel Communication Server 1000:
Table of Contents

Advertisement

Option
AL2 Threshold
AL2 Duration
Frame Slip
Threshold
Frame Slip
Duration
Note:
If the duration period is set too long, the Lineside T1 card can be slow to return to service
automatically even when the carrier is no longer experiencing any errors. The Clear Alarm
command must be entered manually to restore service promptly. To avoid this, the duration
period should normally be set to 10 seconds.
Set Clearing
Use the Set Clearing (S C) command set to enable or disable alarm self-clearing. Answer Y
or N to the question: "Enable Self Clearing? (YES or NO)". If "Enable Self-Clearing" is chosen
(the factory default condition), the system automatically clears alarms after the alarm condition
is no longer detected for the corresponding duration period.
The "Disable Self-Clearing" option causes the system to continue the alarm condition until the
Clear Alarm (C A) command set is entered. Line processing and the yellow alarm indication to
the CPE is terminated as soon as the alarm condition clears, even if "Disable Self-Clearing" is
set.
Display Configuration
The Display Configuration (D C) command set displays the various configuration settings
established for the Lineside T1 card. Entering the Display Configuration (D C) command set
causes a screen similar to the following to appear:
LTI S/N 1103 Software Version 1.01
Alarms Enabled: YES
Alarm Level 1 threshold value: E-7
(in seconds): 10
Alarm Level 2 threshold value: E-5
(in seconds): 1
Frame slips alarm level threshold: 5
(in hours): 2
Current dip switch S1 settings (S1..S8) On Off Off On Off
Off Off On
Circuit Card Reference
Sets the allowable bit errors per second (from 3 to 9) before alarm level
2 is activated. Factory default is 10
Sets the duration in seconds (from 1 to 3,600 seconds) that alarm level
2 is activated. Factory default is 10 seconds.
Sets the allowable frame slips per time period (from 1 to 255) before alarm
level 2 is activated. Factory default is 5.
Sets the duration in hours (from 1 to 24) that the frame slips are counted.
After this time period, the counter is reset to 0. Factory default is 2
hours.
Self Clearing Enabled: YES
Man-Machine T1 maintenance interface software
Description
-5
.
3/03/95 1:50
Threshold duration
Threshold duration
Threshold duration
July 2011
183