NT5D11 and NT5D14 Lineside T1 Interface cards
When the card is used to service off-premise terminal equipment through the public telephone
network, install a Channel Service Unit (CSU) as part of the terminal equipment to provide
external line protection.

Environmental specifications

Table 70: Lineside T1 card - environmental specifications
specifications of the Lineside T1 card.
Table 70: Lineside T1 card - environmental specifications
Operating temperature-normal
Operating temperature-short term
Operating humidity-normal
Operating humidity-short term
Storage temperature
Storage humidity

Installation and configuration

Installation and configuration of the Lineside T1 card consists of six basic steps:
1. Configure the dip switches on the Lineside T1 card for the environment.
2. Install the Lineside T1 card into the selected card slots in the IPE shelf.
3. Cable from the I/O panel to the Customer Premise Equipment (CPE) or CSU, MMI
4. Configure the MMI terminal.
5. Configure the Lineside T1 card through the system software and verify self-test
6. Verify initial T1 operation and configure MMI (optional).
Steps 1-5 are explained in this section. Step 6 is covered in
interface software

Dip switch settings

Begin the installation and configuration of the Lineside T1 card by selecting the proper dip
switch settings for the environment. The Lineside T1 card contains two dip switches, each
158
Circuit Card Reference
Parameter
terminal or modem (optional), external alarm (optional), and other Lineside T1 cards
for daisy chaining use of MMI terminal (optional).
results.
on page 175.
Comments? infodev@avaya.com
on page 158 lists the environmental
Specifications
15° to +30° C (+59° to 86°F), ambient
10° to +45° C (+50° to 113°F), ambient
20% to 55% RH (non-condensing)
20% to 80% RH (non-condensing)
–50° to +70° C (–58° to 158°F), ambient
5% to 95% RH (non-condensing)