NT8D09 Analog Message Waiting Line card
Power requirements
Table 165: Power requirements
Analog Message Waiting Line card.
Table 165: Power requirements
Voltage (+/-)
+ 12.0 V DC
+ 8.0 V DC
–48.0 V DC
–48.0 V DC
86.0 V AC
–150.0 V DC
Note:
1. Each active ringing relay requires 10 mA of battery voltage.
Note:
2. Reflects the current for ringing a single station set (or DN telephone). There may be
as many as five ringers on each line.
Foreign and surge voltage protections
In-circuit protection against power line crosses or lightning is not provided on the Analog
Message Waiting line card. When the Analog line card is used to service off-premise
telephones, the NTAK92 Off-premise protection module must be used. Check local regulations
before providing such service.
372
Circuit Card Reference
2.5 dB loss for PCM to analog
on page 372 provides the power requirements for the NT8D09
Tolerance
0.36 V DC
0.40 V DC
2.00 V DC
5.00 V DC
5.00 V AC
3.00 V DC
Comments? infodev@avaya.com
Idle current
Active
current
48 mA
0 mA
150 mA
8 mA
48 mA
40 mA
0 mA
10 mA
(Note 1)
0 mA
10 mA
(Note 2)
0 mA
2 mA
Max
48 mA
280
mA
688
mA
320
mA
160
mA
32 mA
July 2011