NT5D33 and NT5D34 Lineside E1 Interface cards
Table 84: LEI card - line interface unit electrical characteristics
Framing
Coding
Signaling
Distance to LTU

Power requirements

Table 85: LEI card - power required
that the LEI requires from the backplane. One NT8D06 IPE Power Supply AC or NT6D40 IPE
Supply DC can supply power to a maximum of eight LEIs.
Table 85: LEI card - power required

Foreign and surge voltage protections

In-circuit protection against power line crosses or lightning strikes is not provided on the LEI.
It does, however, protect against accidental shorts to –52 V dc analog lines.
When the card is used to service off-premise terminal equipment through the public telephone
network, install a Line Termination Unit (LTU) as part of the terminal equipment to provide
external line protection.

Environmental specifications

Table 86: LEI card - environmental specifications
specifications of the LEI.
Table 86: LEI card - environmental specifications
Operating temperature – normal
204
Circuit Card Reference
Characteristics
Voltage
5.0 V dc
+15.0 V dc
-15.0 V dc
Parameter
Comments? infodev@avaya.com
Description
CRC-4 or FAS, only
AMI or HDB3
Loop or ground start A/B robbed-bit
0-199.6 meters (0-655 feet)
on page 204 shows the voltage and maximum current
Max. Current
on page 204 shows the environmental
Specifications
15° to +30° C (+59° to 86° F), ambient
1.6 Amp
150 mA
150 mA