Environmental Specifications; Front Panel Features (Front View Without The Front Bezel) - Avaya callpilot 1002rp Hardware Installation

Hide thumbs Also See for callpilot 1002rp:
Table of Contents

Advertisement

1002rp server description
Weight of fully loaded system

Environmental specifications

Environmental condition
Operating temperature
Non-operating (storage) temperature
Non-operating humidity
Altitude
Electrostatic discharge
Acoustic noise
Operating shock
Handling drop

Front panel features (front view without the front bezel)

The front view of the 1002rp server chassis shows redundant dual fans to the left and the
right of the status panel. The left drive bay holds six SCSI hard drives with hot-pluggable
carriers. The media drive bay, located to the right, houses the CD-ROM, tape drive, and floppy
disk drive.
®
12
Avaya CallPilot
1002rp Server Hardware Installation
45.5 kg (100 lb)
Specification
10°C to 35°C (50°F to 95°F) Maximum rate
of change must not exceed 10°C (50°F) per
hour.
-40°C to 70°C (-40°F to 158°F)
95%, non-condensing at 30°C (86°F)
1829 m (6000 ft)
15 kV or more
50 dBA in a typical office ambient
temperature (18°C to 25°C [64.4°F to 77°F])
No errors with a half sine wave shock of 2G
(with 1 millisecond duration)
Operational after a free fall from 450 mm to
600 mm (18 in. to 24 in.) (depending on
weight)
December 2010

Advertisement

Table of Contents
loading

Table of Contents