Digit
3
4
5
6
7
8
9
10
11
12
13
14
15
The exact meaning of each MFC signal number (1-15) within each level can be programmed
separately for each trunk route using MFC. This programming can be done by the customer
and allows users to suit the needs of each MFC-equipped trunk route.
Each MFC-equipped trunk route is associated with a data block that contains the MFC signal
functions supported for that route.

MFE signaling

The NT5K21 XMFC/MFE card can be programmed for MFE signaling which is used mainly in
France. MFE is much the same as MFC except it has its own set of forward and backward
signals.
Table 136: MFE Frequency values
for MFE. The one backward signal for MFE is referred to as the "control" frequency.
Table 136: MFE Frequency values
Digit
1
2
3
Circuit Card Reference
Forward direction DOD-Tx, DID-
Rx
1500 Hz + 1620 Hz
1380 Hz + 1740 Hz
1500 Hz + 1740 Hz
1620 Hz + 1740 Hz
1380 Hz + 1860 Hz
1500 Hz + 1860 Hz
1620 Hz + 1860 Hz
1740 Hz + 1860 Hz
1380 Hz + 1980 Hz
1500 Hz + 1980 Hz
1620 Hz + 1980 Hz
1740 Hz + 1980 Hz
1860 Hz + 1980 Hz
on page 297 lists the forward and backward frequencies
Forward direction OG-Tx, IC-Rx
700 Hz + 900 Hz
700 Hz + 1100 Hz
900 Hz + 1100 Hz
backward direction DOD-Rx, DID-
Tx
1020 Hz + 900 Hz
1140 Hz + 780 Hz
1020 Hz + 780 Hz
900 Hz + 780 Hz
1140 Hz + 660 Hz
1020 Hz + 660 Hz
900 Hz + 660 Hz
780 Hz + 660 Hz
1140 Hz + 540 Hz
1020 Hz + 540 Hz
900 Hz + 540 Hz
780 Hz + 540 Hz
660 Hz + 540 Hz
Backward direction
1900 Hz (Control Frequency)
MFE signaling