9.7 Error Messages in GP-GL Command Mode

Symptom
ERROR 1
COMMAND ERROR
ERROR 4
PARAMETER
OVERFLOW
ERROR 5
I/O ERROR
T E S T M O D E S A N D T R O UB L E S H O O T I N G : E r r o r M e ss a g e s i n G P - G L C o m m a n d M o d e
Cause
The plotter received an unrecognizable
command.
• Noise was input to the plotter upon
execution of the software application.
• The software configuration regarding the
output device has been changed.
• The plotter's interface conditions have
been changed.
A command was received containing
numeric parameters that exceed that
command's permissible range.
• The software configuration regarding the
output device has been changed.
• The plotter's interface conditions have
been changed.
An error occured in the receipt of data
within the interface.
• The software command settings for
connecting changed,
• The plotter's interface conditions have
been changed.
Solution
Press the ENTER key.
Configure the software to drive your
plotter.
Ensure that the software's interface
conditions are correctly set.
Ensure that the plotter's interface
conditions are set to match those of the
software.
Configure the software to drive your
plotter.
Ensure that the software's interface
conditions are correctly set.
Ensure that the plotter's interface
conditions are set to match those of the
software.
Configure the software to drive your
plotter.
Ensure that the software's interface
conditions are correctly set.
Ensure that the plotter's interface
conditions are set to match those of the
software.
9-11