PictureTel LIVE50 Installation Manual page 163

Table of Contents

Advertisement

Information Category
Line Code
Digital Subscriber Line (DSL)
Provisioning Parameters
Terminal Service Profile Data:
Access Data:
* NI-1 was first supported in the APS 11 software release.
NOTE: Some fields might vary from one switch to another. Voice DN might be different from CMD DN.
Siemens EWSD NI-1 Switch Settings
Specific Options
2B1Q
National*
BCHDNs = 2 (directory numbers assigned by telephone company)
BCDN = C56
BCDN = C64 (if supported by interexchange carrier to local central office)
CT = CMD (circuit mode data)
TSPIDs assigned by telephone company: Two
BRI should be provisioned as follows:
Subscriber
- Set B1 CT = CMD (for circuit switched data/voice)
- Set B2 CT = CMD (for circuit switched data)
- BCHCT = 2
- IBCHCT = 2
- OBCHCT = 2
- COS = NICND (class of service; no ISDN calling # delivery)
- PIC = XXX-C56 (where XXX is the interexchange carrier's code)
- PIC = XXX-C64 (where XXX is the interexchange carrier's code)
- USID = 1 (user ID)
- TSPID = 7085551234001 (for illustration purposes)
- TERMLIM = 1 (maximum number of terminals that can share this SPID)
- CT = CMD
- FKMPINUM = 0 (feature key management profile index number)
- BCHEQN = 2 (number of B-channels assigned)
- BEQN = SP & AU3 & C56 & C64 (bearer capabilities on BRI)
- COE = CLASS1 (class of equipment)
- LINKOPT = DYNNOPL (dynamic link, no packet links)
- CPDDN = 7085551234-CMD - The directory numbers assigned bt the telephone
company must match the bearer capabilities requested. In this example, the single
number listed is for circuit mode data. For this application, two DN's are requested.
- CPVDN2 = 7085551235
What You Need to Provide
D-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Live100

Table of Contents