The I/O port address takes the form:
0xy0
where:
0 is preset and is not defined by a switch.
x is designated with switches 5 and 6 and can be digits 0, 1, 2,
or 3.
y is designated with switches 1 through 4 and can be digits 0
through F.
0 is preset and is not defined by a switch.
I/O port addresses are expressed in hexadecimal and can be
assigned a value from 0000 to 03F0 in increments of 16
(10 hexadecimal).
Note: These switch settings do not follow the same scheme as
the settings on the Live100 Audio Communications
board.
To set the I/O port address on your Switched-56 Network Interface
board:
1. Make sure that the back plate (with the connectors) is facing
toward your right.
2. For the digit in position x, set switches 5 and 6 accordingly.
Use a thin, blunt instrument, such as a ballpoint pen.
Do not use a pencil; the graphite can damage the switches.
Installing the Switched-56 Network Interface Board