Control Panel Sets

JUPITER L-S and LCD Series Control Panel Instruction Manual
- Output Set name. Creation of CP Output Sets is described in the
Output Set
Jupiter CM-4000 Installation and Operating Manual.
• For an S25 or S50 panel, with entry of a single Destination name, the
panel will operate as a one-Destination panel. The eight-button cluster
on the right-hand side of the panel will be used to control the first eight
levels of the router.
• For an S25 or S50 panel, with selection of an Output Set with two, three,
or four Destinations defined, the panel will operate as a two-, three-, or
four-Destination panel respectively. With respect to the eight-button
cluster on the right-hand side of the panel, the top row of four buttons
will be used to select the Destination; the bottom row of four buttons
will be used to control the first four levels of the router.
• For an S25 or S50 panel, with selection of an Output Set with five, six,
seven, or eight Destinations defined, the panel will operate as a five-,
six-, seven-, or eight-Destination panel respectively. The eight-button
cluster on the right-hand side of the panel will be used to select the Des-
tination.
• For all other L-S series panels, if an actual CP Output Set is selected,
then the control panel will be able to control all the Destinations listed
in that Set; depending on the contents of the set, this would allow for
full-matrix or multi-bus control. Alternatively, this field can be used to
enter the name of a single switcher Destination to be controlled; the
Source of the Destination name is the Switcher Output table.
- This column is not used for L-S panels.
Out Panel
- Select the CP Level Set name.
Level Set
- (Does not apply to S25 and S50. Optional for all other L-S
Override Set
panels.) Select a CP Override set name. A CP Override set can be used to
define a set of Sources and level combinations that can be quickly applied
to a panel controlled Destination. Up to 10 pages of overrides (80 total) may
be defined. The order in which the overrides are listed on the CP Override
set table will be the order in which they appear on the panel.
- Select a CP Sequence set name. A Sequence set is used to
Sequence Set
execute a list of switches with a single command. (Does not apply to S25
and S50and is optional for all other L-S panels.)
Switcher Sources and Destinations for the L-S panels are specified by cre-
ating a Jupiter CP Level Set, a CP Input Set, and a CP Output Set. These sets
are assigned to each panel using the MPK Devices table
Control Panel Sets
(Figure
26).