Control Panel Sets; Cp Level Set; Cp Input And Cp Output Sets - GRASS VALLEY JUPITER L - V2.1.0 Instruction Manual

L, s, and lcd series control panels
Table of Contents

Advertisement

Control Panel Sets

CP Level Set

CP Input and CP Output Sets

JUPITER L-S and LCD Series Control Panel Instruction Manual
- (Does not apply to S25 and S50. Optional for all other L-S
Override Set
panels.) Select a CP Override set name. A CP Override set can be used to
define a set of Sources and level combinations that can be quickly applied
to a panel controlled Destination. Up to 10 pages of overrides (80 overrides
total) may be defined. The order in which the overrides are listed on the CP
Override set table will be the order in which they appear on the panel.
- Select a CP Sequence set name. A Sequence set is used to
Sequence Set
execute a list of switches with a single command. (Does not apply to S25
and S50and is optional for all other L-S panels.)
Switcher Sources and Destinations for the L-S panels are specified by cre-
ating a Jupiter CP Level Set, a CP Input Set, and a CP Output Set. These sets
are assigned to each panel using the MPK Devices table
The CP Level Set used for L-S panels is specified as type CP3800.
With L-S panels, the CP Level Set establishes the order in which levels are
displayed on the panel and the display mnemonics used for the various
levels ("Video," "Left," etc.). The display mnemonics have a maximum
length of eight characters.
The CP Input and Output Set is specified as type CPESXTND for all L-S and
LCD models. The number of category buttons varies from panel to panel,
as indicated in
Table
1.
Table 1. Panel Category Buttons
Number of Category
L-S Panel Model
Buttons (default)
L32
None
L64
None
LD4
16
LD16
20
S25
None
S50
None
S100
None
SXY
16
LCD
98 (20 categories at a time)