GRASS VALLEY L-S series Instruction Manual page 60

Table of Contents

Advertisement

Section 4 — Jupiter System Configuration
60
Note
Panels can be configured to force unlock and force un-protect any destination
regardless of what panel locked or protected it, depending on what is entered
in the Password column. See the 7.8.1 Jupiter Release notes (part #
071827511) for more information.
- Name of CM-4000 associated with this panel. The Source of this
Board
name is the Network Description table.
- Not used for a LAN-only installation.
Port
- Panel address from 01 to 64 (01 to 16 for Serial). Must be unique for
Address
panels that are associated with the same CM-4000. L-S panels are normally
shipped with a panel address of "01." This number is referred to as the
"Device Number" on the IP configuration page and "ID" within the L-S
menu system.
- The name of the CP Input set that will be assigned to this panel.
Input Set
The usual practice is to have one CP Input Set, containing the names of all
Sources, applied to all panels. However, special CP Input Sets could be
created which list only selected Sources; such a set could be used to prevent
certain panels from selecting specific Sources.
• For a Button-per-Source panel (L32, L64, S25, S50, S100) the CP Input
set can be used to assign Sources to specific Source buttons where the
first Source in the table corresponds to the first button on the panel, etc.
- This column is not used for L-S panels.
In Panel
JUPITER L-S and LCD Series Control Panel Instruction Manual

Hide quick links: