Cp Level Set; Cp Input And Cp Output Sets - GRASS VALLEY L-S series Instruction Manual

Table of Contents

Advertisement

Section 4 — Jupiter System Configuration

CP Level Set

CP Input and CP Output Sets

62
The CP Level Set used for L-S panels is specified as type CP3800.
With L-S panels, the CP Level Set establishes the order in which levels are
displayed on the panel and the display mnemonics used for the various
levels ("Video," "Left," etc.). The display mnemonics have a maximum
length of eight characters.
The CP Input and Output Set is specified as type CPESXTND for all L-S and
LCD models. The number of category buttons varies from panel to panel,
as indicated in
Table
1.
Table 1. Panel Category Buttons
Number of Category
L-S Panel Model
Buttons (default)
L32
None
L64
None
LD4
16
LD16
20
S25
None
S50
None
S100
None
SXY
16
LCD
98 (20 categories at a time)
For example, the LD4 panel provides a maximum of 16 categories; therefore
categories 17 through 98 (as shown by the Jupiter editor) will not be sup-
ported. The CP Input and Output sets are also the Source of the eight-char-
acter mnemonics displayed on the panel.
Further, the CP Input set determines which of the S25, S50, S100, L32, and
L64 Button-per-Source buttons is assigned to which Source. The upper left-
hand button of the panel will select the first Source listed on the CP Input
Set created and selected for this particular panel, the next button to the
right will select the next listed Source, etc.
Note
The total number of units (Jupiter Entry Numbers) within a category is limited
to 4096. For example, the total number of machines within category "VTR" is
limited to 4096.
JUPITER L-S and LCD Series Control Panel Instruction Manual