e. Select "Edit."
f.
IP address - set to a unique value within the same network as the
Jupiter file server.
For example, if the Jupiter file server address is 192.168.253.1, then
the panel address should be changed to reside in the 192.168.253.x
network (such as "192.168.253.101").
g. Subnet Mask - set to 255.255.255.0 (Class C network).
h. Gateway - not used in a simple network environment.
If the panel and the server are on separate networks, the gateway
connecting them must be specified. See
i.
Select "OK," "Apply Changes," and "Close."
In the IP View, a green dot should indicate that the panel is fully
connected.
The panel itself should reboot.
j.
Proceed to
Setting Jupiter Values for L-S Panels
During the following steps, you will need to know the IP address of the
CM-4000 that will be associated with the panel. Use the Jupiter File Server
JNS Control Center application to determine the CM-4000 IP address (the
Control Center application is described in the Jupiter CM-4000 Installation
and Operating Manual).
1. Using NetConfig, click on the name of the panel (as described in
above).
You should see the Product Web Access page for the panel.
2. Select "Panel Network."
You should see the Panel Network Configuration page.
a. The "Net-1 IP Settings" should already be correct (they were set
using the "Change IP Addresses" menu described above).
b. Uncheck "Net-1: Set DHCP Mode" and "Net-2: Set DHCP Mode"
(unless IP addresses are being set automatically by a Dynamic Host
Configuration Protocol server).