GRASS VALLEY OCP400/20 Maintenance Manual

GRASS VALLEY OCP400/20 Maintenance Manual

Operational control panel

Advertisement

Quick Links

OCP400/20-30
Operational Control Panel
Maintenance Manual
3922 496 30261
2022-12-12 V11
www.grassvalley.com

Advertisement

Table of Contents
loading

Summary of Contents for GRASS VALLEY OCP400/20

  • Page 1 OCP400/20-30 Operational Control Panel Maintenance Manual 3922 496 30261 2022-12-12 V11 www.grassvalley.com...
  • Page 3: Patent Information

    Valley USA, LLC, or one of its affiliates or subsidiaries. All other intellectual property rights are owned by GVBB Holdings SARL, Grass Valley USA, LLC, or one of its affiliates or subsidiaries. All third party intellectual property rights (including logos or icons) remain the property of their respective owners.
  • Page 4: Important Safety Information

    Use anti-static procedures, equipment and surfaces during servicing. The presence of this symbol in or on Grass Valley equipment means that it has been tested and certified as complying with applicable Underwriters Laboratory (UL) regulations and recommendations for USA.
  • Page 5 Notices Warnings A warning indicates a possible hazard to personnel, which may cause injury or death. Observe the following general warnings when using or working on this equipment: • Any instructions in this manual that require opening the equipment cover or enclosure are for use by qualified service personnel only.
  • Page 6: Electrostatic Discharge (Esd) Protection

    • Do not leave the OCP 400 in direct sunlight or close to heating appliances for extended periods. • Do not connect Grass Valley OCP 400 with other manufacturer’s camera system parts. • Make connections swiftly and firmly to avoid false error messages.
  • Page 7: Environmental Information

    Grass Valley believes this environmental information to be correct but cannot guarantee its completeness or accuracy since it is based on data received from sources outside our company. All specifications are subject to change without notice.
  • Page 8: Laser Safety

    OCP 400 Maintenance Manual Laser Safety - Fiber Output SFP and QSFP Modules Warning LASER SAFETY The average optical output power does not exceed 0 dBm (1mW) under normal operating conditions. Unused optical outputs should be covered to prevent direct exposure to the laser beam.
  • Page 9: Safety And Emc Standards

    Notices Safety and EMC Standards This equipment complies with the following standards: Safety Standards IEC62368-1:2018 Audio/video, information and communication technology equipment: part 1 EN 62368-1:2018 EU national deviations. EMC Standards This unit conforms to the relevant Union harmonization legislation and the requirements of the following directive/standards: RED 2014/53/EU EMC testing;...
  • Page 10 OCP 400 Maintenance Manual This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
  • Page 11 Notices...
  • Page 12: Coaxial Cables

    Maintenance Manual EMC performance of cables and connectors Grass Valley products are designed to meet or exceed the requirements of the appropriate European EMC standards. In order to achieve this performance in real installations it is essential to use cables and connectors with good EMC characteristics.
  • Page 13 Notices...
  • Page 14 8926 464 0x001 - CONTR. PANEL OCP400 JOYSTICK List of Field Replacable Units (FRUs): Part Number Description Quantity 8926 590 30001 AC ADAPTER 15Volts / 3,34AMPS 500-00080-01 ASSY MONOKNOB WIRED...
  • Page 16 SCREW M5X1.7 3922 404 32483 SCREW M5X21.5 PCBA ETHERNET-DATA BOARD OCP400/30 522-00062-01 90-00159-000 PCBA ETHERNET-DATA BOARD OCP400/30 ETHERNET-DATABOARD OCP400/20 522-00027-01 3922 406 50311 PCBA OCP CONNECTOR BOARD 3922 496 30101 SERV.ASSY OCP KEY ROTARY BRD 3922 496 30111 SERVICE ASSY OCP KEY LED BRD 3922 496 30123 SERV.ASS.PREVIEW KNOB OCP400...
  • Page 18 500-00080-01 - ASSY MONOKNOB WIRED List of Field Replacable Units (FRUs): Part Number Description Quantity 500-00080-01 ASSY MONOKNOB WIRED Complete assembly 500-00073-01 WIRING MONOKNOB ASSY 3922 208 00168 POTM 53SAD-U22-B15L 522-00065-01 PCBA EM14 ENCODER...
  • Page 19 Assembly instructions POS 10...
  • Page 20 3922 496 31041 - SERVICE ASSY KNOBS OCP400 List of Field Replacable Units (FRUs): Part Number Description Quantity 3922 496 31041 SERVICE ASSY KNOBS OCP400 ↓ FRU kit contains Parts cannot be ordered separately 2422 129 16907 SWITCH EAO 95-313.000 DATE CODE > 34607 3922 203 00010 CONTR.KNOB BLUE DIA 12 SH.6 3922 203 00011...
  • Page 21: Light Guide

    3922 496 31041 - SERVICE ASSY KNOBS OCP400 (FRU) LENS FOR SWITCH SQ19 MM LENS FOR SWITCH SQ12.7 MM DIFFUSER FOR SWITCH SQ19 DIFFUSER FOR SWITCH SQ12.7 SWITCH EAO 95-313.000 CONTR.KNOB BLUE/GREY/RED/GREEN DIA 12 SH.6 SMALL BUTTON TOP OPALE CAP LIGHT GUIDE COMPRESS.SPRING 0.2X1.6X13.3 BUTTON GUIDE...

This manual is also suitable for:

Ocp400/30

Table of Contents