Jupiter System Configuration

MPK Table Entries

MPK Devices
MPK
Device
Devices
Type
1
JEP1
CPESXTND
JEP2
CPESXTND
2
JEP64
CPESXTND
64
JUPITER L-S and LCD Series Control Panel Instruction Manual
The following overview of L-S series panel configuration assumes that the
reader is familiar with the Jupiter Facility Control System. Please refer to
the Jupiter CM-4000 Installation and Operating Manual for specific informa-
tion.
The Jupiter MPK table is used for configuration purposes. The example
shown in
Figure 26
Note
A Serial Device entry in the MPK table is required whether it is used or not.
This entry can be an ASCII or an ESSwitch Device type. For instructions on
defining an ASCII or an ESSwitch port, see the Jupiter manual (part #
071826104).
Figure 26. MPK Devices Table
Pass
Expansion
Board
Port
Address
word
CM1
01
75
CM1
02
CM1
64
92
- This column is used to create a name, up to eight characters in
MPK Devices
length, for each L-S panel. This name must be unique system-wide.
- Select type
Device Type
- For L-S series panels, leave unchecked.
Expansion
- Password level only needs to be entered if you wish to disable the
Password
Configuration and Setup menus on the Control panel. See the
Configuration and Setup Menus on the Control Panel
information.
applies to the system shown in
Input Sets
In Panel
Output Sets
KXYZOUT
KXYZINP
KXYZINP
KXYZOUT
KXYZINP
KXYZOUT
CPESXTND
from the pull-down menu.
"
"
Section
Figure 23 on page
Out Panel
Level Set
Overide Set
KXYZLEV
KXYZLEV
KXYZLEV
Disabling the
section below for more
4
53.
Sequence Set
K
59