6028 Series Quick Setup Guide
Configuration and Connection
Step 1: Select Control System
Control panel modes are set using DIP switch 6. See table below:
Step 1: Select Control System
LED control panel modes are set using DIP switches 5 – 9. See table below
LCD control panel modes are set using DIP switches 1
UP = 6711 Mimic (BPX or Freeform)
Step 3: Connect Power
Plug cable into 2A fused IEC
socket
LCD Control Panel Modes
Note: Mode must match database configuration. A mismatch is not flagged – switches may still light and
control router crosspoints.
Set DIP switches 5 – 9
According to the table to set
the control panel
DIP Switches
Step 4: Setup Comms
Connect the appropriate cable to a comms port (serial or Ethernet) and configure the port address
-
Standard RS232/485 pinout Serial Cable
-
Standard CAT-5 10/100 BASE-T straight-through or crossover Ethernet cable
16 Way BPX
Dual 8 Split BPX
8x8 X‐Y
16x4 X‐Y (no level keys)
32 Way BPX
Dual 16 Split BPX
16x16 X‐Y
32x4 X‐Y (no level keys)
48 Way BPX
Dual 24 Split BPX
48x4 X‐Y (no level keys)
32x16 X‐Y
Dual 16+16 BPX
16x16 X‐Y
24x12 X‐Y
User Defined
3
Step 2: Select Comms Type
Set DIP switch 10:
UP = RS485 (serial)
DOWN = Ethernet
DIP Switches
5
6
Up
Up
Down
Up
Up
Down
Down
Down
Up
Up
Down
Down
Up
Down
Up
Down
Down
Down
Down
Down
Up
Up
Down
Up
Down
Down
Up
Up
Down
Down
Up
Down
Up
Down
Down
Down
Down
Down
Up
Up
7
8
9
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
Down
Up
Up
Down
Up
Up
Down
Up
Down
Up
Down
Up
Down
Up
Down
Up
Up
Up
Down