Checking generator stator windings resistance (1)

Disconnect the stator coil connector from the wiring and measure resistance
with a meter.
1
H10468
1) Measure across the terminals of the connector (2); correct value is about
2
0.1 - 1.0
If resistance is outside the specified limits, replace the complete generator.
H10484

Generator performance

12V / MAX 390W.
AT EACH ENGINE OVERHAUL, CLEAN FLYWHEEL ROTOR TO
REMOVE ANY DEBRIS SUSPENDED IN SWIRLING OIL AND CAP-
TURED BY THE MAGNETS.
.
M.16