Issue 13.0
The following Dial Options will be used:
Message 1: Day Main Greeting and has the following dial options:
3 = Routes callers to message 3 which is used for office hours and direction information in the Day
Mode.
4 = Allows callers to leave a message.
0 = Routes callers to the Operator's extension 101. You can only enter valid extension numbers in this
field and cannot use '0' as the routing destination.
Message 2: Night Main Greeting, since this is used after hours there is no option to route callers to
the Operator and has the following dial options:
3 = Routes callers to message 4 which is used for office hours and direction information in the Night
Mode.
4 = Allows callers to leave a message.
Message 3: Day Informational Greeting and has the following dial options:
3 = Replays Message 3.
4 = Allows callers to leave a message.
0 = Routes callers to the Operator's extension 101. You can only enter valid extension numbers in this
field and cannot use '0' as the routing destination.
# = Routes callers back to the Day Main Greeting (Message 1).
Message 4: Night Informational Greeting, since this is used after hours there is no option to route
callers to the Operator and has the following dial options:
3 = Replays Message 4.
4 = Allows callers to leave a message.
# = Routes callers back to the Night Main Greeting (Message 2).
Programming:
This example assumes the default Class of Service (COS) settings have not been changed,
extension 101 is still in COS 15 and used as the Operator's extension.