Download Print this page

Subaru 2009 IMPREZA Service Manual page 687

Hide thumbs Also See for 2009 IMPREZA:

Advertisement

Diagnostic Procedure with Diagnostic Trouble Code (DTC)
ENGINE (DIAGNOSTICS)
Step
7
CHECK MASS AIR FLOW AND INTAKE AIR
TEMPERATURE SENSOR.
1) Start the engine and warm up engine until
coolant temperature is higher than 75°C
(167°F).
2) For AT models, set the select lever to "P"
range or "N" range, and for MT models, place
the shift lever in the neutral position.
3) Turn the A/C switch to OFF.
4) Turn all the accessory switches to OFF.
5) Read the data of the mass air flow and
intake air temperature sensor signal using Sub-
aru Select Monitor or general scan tool.
NOTE:
• Subaru Select Monitor
For detailed operation procedures, refer to
"READ CURRENT DATA FOR ENGINE". <Ref.
to EN(H4SO)(diag)-34, Subaru Select Moni-
tor.>
• General scan tool
For detailed operation procedures, refer to the
general scan tool operation manual.
8
CHECK MASS AIR FLOW AND INTAKE AIR
TEMPERATURE SENSOR.
1) Start the engine and warm up engine until
coolant temperature is higher than 75°C
(167°F).
2) For AT models, set the select lever to "P"
range or "N" range, and for MT models, place
the shift lever in the neutral position.
3) Turn the A/C switch to OFF.
4) Turn all the accessory switches to OFF.
5) Open the front hood.
6) Measure the ambient temperature.
7) Read the data of the mass air flow and
intake air temperature sensor signal using Sub-
aru Select Monitor or general scan tool.
NOTE:
• Subaru Select Monitor
For detailed operation procedures, refer to
"READ CURRENT DATA FOR ENGINE". <Ref.
to EN(H4SO)(diag)-34, Subaru Select Moni-
tor.>
• General scan tool
For detailed operation procedures, refer to the
general scan tool operation manual.
9
CHECK OUTPUT SIGNAL OF ECM.
1) Turn the ignition switch to ON.
2) Measure the voltage between ECM and
chassis ground on faulty cylinders.
Connector & terminal
#1 (B137) No. 8 (+) — Chassis ground (–):
#2 (B137) No. 9 (+) — Chassis ground (–):
#3 (B137) No. 10 (+) — Chassis ground (–):
#4 (B137) No. 11 (+) — Chassis ground (–):
Check
Is the measured value 2.0 —
5.0 g/s (0.26 — 0.66 lb/m)?
Subtract ambient temperature
from intake air temperature. Is
the obtained value –10 — 50°C
(–18 — 90°F)?
Is the voltage 10 V or more?
EN(H4SO)(diag)-270
Yes
No
Go to step 8.
Replace the mass
air flow and intake
air temperature
sensor. <Ref. to
FU(H4SO)-34,
Mass Air Flow and
Intake Air Temper-
ature Sensor.>
Go to step 9.
Check the mass air
flow and intake air
temperature sen-
sor. <Ref. to
FU(H4SO)-34,
Mass Air Flow and
Intake Air Temper-
ature Sensor.>
Go to step 14.
Go to step 10.

Advertisement

loading