E: INSPECTION
1. TIP CLEARANCE
Measure the tip clearance of rotors. If the clearance
is out of specification, replace the rotors as a set.
Tip clearance:
Standard:
0.04 — 0.14 mm (0.0016 — 0.0055 in)
2. CASE CLEARANCE
Measure the clearance between the outer rotor and
the oil pump case. If clearance is out of standard,
replace the oil pump case.
Case clearance:
Standard:
0.10 — 0.175 mm (0.0039 — 0.0069 in)
Oil Pump
3. SIDE CLEARANCE
Measure the gap between the inner rotor and the
oil pump case to measure the clearance between
the oil pump inner rotor and the oil pump cover as
shown in the figure. If clearance is out of standard,
replace the rotor or the oil pump case.
Side clearance:
Specification:
0.02 — 0.07 mm (0.0008 — 0.0028 in)
LU-00023
4. OIL RELIEF VALVE
Check the valve for assembly condition and dam-
age, and the relief valve spring for damage and de-
terioration.
Replace the parts if defective.
Relief valve spring:
Free length
73.7 mm (2.902 in)
Installed length
54.7 mm (2.154 in)
Load when installed
93.1 N (9.49 kgf, 20.88 lbf)
5. OIL PUMP CASE
Check the oil pump case for worn shaft hole,
clogged oil passage, worn rotor chamber, cracks
LU-00024
and other faults.
6. FRONT OIL SEAL
Check the front oil seal lips for deformation, hard-
ening, wear, etc. and replace if defective.