Download Print this page

Subaru 2009 IMPREZA Service Manual page 415

Hide thumbs Also See for 2009 IMPREZA:

Advertisement

3. STATOR
1) Continuity test
Inspect continuity between the stator coil lead wire
terminals. If the resistance is 1 M
lead wire is damaged. Replace the stator assem-
bly.
(A)
(A) Stator
2) Insulation test
Inspect the continuity between the stator coil stator
core and lead wire terminals. If the resistance is 1
or less, the stator coil is grounded. Replace the sta-
tor assembly.
Generator
4. BRUSH
1) Measure the length of each brush. Replace the
brush if wear exceeds service limits. There is a ser-
vice limit mark (A) on each brush.
or more, the
Brush length:
Standard
Service limit
SC-00047
2) Check that there is appropriate pressure on the
brush spring.
Using a spring pressure indicator, push the brush
into the brush holder until its tip protrudes 2 mm
(0.08 in). Then measure the pressure of brush
spring. If the pressure is 2.648 N (270 g, 9.52 oz)
or less, replace the brush spring with a new part.
4.609 — 5.786 N (470 — 590 g, 16.58 — 20.810 oz)
pressure is required on the new spring.
SC-00048
5. BEARING (FRONT SIDE)
Check the front ball bearing. Replace the ball bear-
ings if there is resistance in the rotation, or if there
is any abnormal noise.
SC(H4SO)-21
STARTING/CHARGING SYSTEMS
18.5 mm (0.728 in)
5.0 mm (0.197 in)
SC-00049
SC-00093

Advertisement

loading