15) Remove purge tube (A), vent tube (B), and
drain tube A (C).
(C)
B: INSTALLATION
Install in the reverse order of removal while being
careful of the following.
• Connect the quick connector as shown in the fig-
ure.
CAUTION:
• Check that there is no damage or dust on the
quick connector. If necessary, clean the seal
surface of the pipe.
• When connecting the quick connector, se-
curely insert the pipe all the way before locking
the retainer.
• If it is not possible to perform the push lock
operation of the retainer, recheck whether the
pipe is securely inserted.
• Make sure that the quick connector is secure-
ly connected.
(a)
(a)
(a) Retainer
Canister
EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES)
(A)
(B)
EC-02294
(a)
EC-02295
EC(H4SO)-7
Tightening torque:
18 N·m (1.8 kgf-m, 13.3 ft-lb)
Tightening torque:
8 N·m (0.8 kgf-m, 5.9 ft-lb)
Tightening torque:
7.5 N·m (0.8 kgf-m, 5.5 ft-lb)
EC-02387
EC-02305
EC-02306