User Guide: PTP 600 Series

Task 11: Connect link to the network

This task consists of the following procedures:

Connecting to the network

Setting the real-time clock
Connecting to the network
To connect to the network, proceed as follows:
Procedure 6-31 Connect to network – in-band management
1
Disconnect the local PC from the PIDU Plus at the Master and Slave sites.
2
At each site, connect the PIDU Plus LAN ports to a router port, switch port
or other network equipment in the data network using the CAT5e cable that
was prepared for this purpose in
page 5-27.
3
Check that the Master and Slave units are reachable from the network
management system by opening the web interface to the management
agents, or by requesting ICMP echo response packets using the Ping
application. The network management system will normally be
geographically remote from the sites, so it may be necessary to request that
this action is completed by co-workers at the management centre.
Alternatively, it may be possible to use remote login to the management
system.
4
Check the data network for correct operation across the wireless link. This
may be by requesting ICMP echo response packets between hosts in the
connected network segments, or by some more structured use of network
testing tools.
phn-0896_012v000
Jul 2010
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299
Task 11: Connect link to the network
on page
6-83
on page
6-84
Preparing the PIDU Plus to LAN cable
on
6-83

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptp 25600Ptp 49600Ptp 54600Ptp 58600Ptp 59600Ptp 48600

Table of Contents