Data rate calculations
Example
Suppose that the link characteristics are:
Product variant = PTP 600 Lite
Link Symmetry = 1:1
Link Mode Optimization = TDM
Modulation Mode = 64QAM 0.92 Dual
Channel Bandwidth = 10 MHz
Link Range = 60 km
The calculation procedure for this example is described in
Procedure 4-2 Example of data rate capacity calculation
1
Use
2
Divide these rates by 2 to give PTP 600 Lite rates:
3
Use
Link Range 60 km. The factor is 0.86.
4
Multiply the rates from Step 2 by the Throughput Factor from Step 3 to
give the throughput capacity of the link:
4-116
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299
Table 4-89
to look up the data throughput capacity rates:
Tx = 41.41 Mbits/s
Rx = 41.41 Mbits/s
Both = 82.81 Mbits/s
Tx = 20.70 Mbits/s
Rx = 20.70 Mbits/s
Both = 41.40 Mbits/s
Figure 4-39
to look up the Throughput Factor for 1:1, TDM and
Tx = 17.80 Mbits/s
Rx = 17.80 Mbits/s
Both = 35.60 Mbits/s