Calculation Procedure And Example - Motorola PTP 600 series User Manual

Ptp 600 series
Hide thumbs Also See for PTP 600 series:
Table of Contents

Advertisement

User Guide: PTP 600 Series

Calculation procedure and example

Procedure
To calculate the data rate capacity of a PTP 600 link, perform
Procedure 4-1 Calculating data rate capacity
1
Use the tables in
up the data throughput capacity rates (Tx, Rx and Both) for the
required combination of:
2
The tables contain data rates for PTP 600 Full only. If the ODUs
are PTP 600 Lite, divide the data rates by 2.
3
The tables contain data rates for links of zero range. Use the
curves in
Throughput Factor that must be applied to adjust the data rates
for the actual range of the link.
4
Multiply the data rates by the Throughput Factor to give the
throughput capacity of the link.
NOTE
phn-0896_012v000
Jul 2010
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299
Data throughput capacity
Link Symmetry
Link Mode Optimization
Modulation Mode
Channel Bandwidth
Range adjustment curves
There is a small difference between the rates for IP and TDM because there
is fragmentation in TDM (for low priority traffic) which causes the
throughput to be reduced buy approximately 1% compared to the IP mode.
Data rate calculations
Procedure
on page
4-117
on page
4-128
to look up the
4-1.
to look
4-115

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptp 25600Ptp 49600Ptp 54600Ptp 58600Ptp 59600Ptp 48600

Table of Contents