Table 4-25 Ptp 48600 Rf Specifications - Motorola PTP 600 series User Manual

Ptp 600 series
Hide thumbs Also See for PTP 600 series:
Table of Contents

Advertisement

User Guide: PTP 600 Series

Table 4-25 PTP 48600 RF specifications

Radio Technology
RF Band
Channel Selection
Dynamic Frequency Control
Channel size
Manual Power Control
Receiver Noise Figure
Antenna Type
Antenna Gain
Antenna Beamwidth
Max Path Loss
Duplex Scheme
Range
Over-the-Air Encryption
Weather Sensitivity
Error Correction
phn-0896_012v000
Jul 2010
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299
4.710-5.000 GHz
Manual selection.
By intelligent Dynamic Frequency Selection (i-DFS) or
manual intervention; automatic selection on start-up and
continual adaptation to avoid interference.
5, 10, 15, and 20 MHz
Maximum power can be controlled lower than the power
limits shown above in order to control interference to other
users of the band.
Typically 5 dB
Integrated flat plate antenna
22 dBi typical
11 Degrees
157 dB (5 MHz channel)
Symmetric fixed, asymmetric fixed or adaptive TDD
125 miles (200km) optical Line-of-Sight
6 miles (10km) non-Line-of-Sight
Proprietary scrambling mechanism.
Sensitivity at higher modes may be reduced during high
winds through trees due to Adaptive Modulation Threshold
changes
FEC
Wireless specifications
Specification