Electromagnetic compliance

Calculated distances and power compliance margins

Table 4-80
and resulting margins for each frequency band and antenna combination. These are
conservative distances that include compliance margins. At these and greater
separation distances, the power density from the RF field is below generally accepted
limits for the general population.
Explanation of terms used in
Tx burst – maximum average transmit power in burst (Watt)
P – maximum average transmit power capability of the radio (Watt)
G – total transmit gain as a factor, converted from dB
S – power density (W/m
d – minimum distance from point source (metres)
R – recommended distances (metres)
C – compliance margin

Table 4-80 Power compliance margins

Band
Antenna
2.5 GHz
Integrated
4.5 GHz
Integrated
4.8 GHz
Integrated
Connectorized
4.9 GHz
Integrated
Connectorized
5.4 GHz
Integrated
External 4ft Dish
4-100
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299
shows calculated minimum separation distances, recommended distances
Table
2
)
Tx burst
(W)
0.25
0.5
0.5
0.5
0.25
0.25
0.005
0.00035
Chapter 4 Reference information
4-80:
P
G
(W)
0.2
63
10
0.4
158
10
0.4
158
10
0.4
398
10
0.2
158
10
0.2
398
10
0.004
200
10
0.00028
2884
10
S
d
R
(W/
(m)
(m)
2
m
)
0.32
2
6.0
0.71
5
7.0
0.71
5
7.0
1.1
5
4.5
0.5
2
4.0
0.8
5
6.25
0.08
1
12.5
0.08