Polycom RMX 2000 Administrator's Manual page 188

Hide thumbs Also See for RMX 2000:
Table of Contents

Advertisement

Chapter 11-RMX Utilities
11-8
Table 11-2
System Flags – MCMS_PARAMETERS (Continued)
Flag
TERMINATE_CONF_
AFTER_CHAIR_
DROPPED
EXTERNAL_DB_PORT
ALLOW_NON_
ENCRYPT_PARTY_IN_
ENCRYPT_CONF
AUTHENTICATE_USER
EXTERNAL_CONTENT_
IP
EXTERNAL_CONTENT_
DIRECTORY
Currently no flags are defined in the CS_MODULE_PARAMETERS
section
3
To modify flag value, double-click the flag.
4
In the New Value field, enter the flag's new value.
Description
Set conference to automatically terminate if
the Chairperson disconnects from the
conference.
Default: YES
The external database server port used by the
RMX to send and receive XML requests/
responses.
Default: 80
Allow non-encrypted participants to connect to
encrypted conferences.
Range: Yes/No (Default: No)
If the external database application is to be
used to verify that operators are authorized to
log in to the MCU, set the value of this flag to
YES.
If the value of this flag is set to NO, the MCU
database is used to verify that operators are
authorized to log in to the MCU.
Note: If the flag is set to YES the flow is first to
look in the internal DB and then go out to the
external one. To work with the external
address book you need to specify.
Flags for SE200 need to be added manually.
The SE200 Web Server IP. This flag is also
the trigger for fetching the external Address
Book.
Flags for SE200 need to be added manually.
The Web Server folder name.
Flags for SE200 need to be added manually.

Advertisement

Table of Contents
loading

Table of Contents