Motorola DSP56303 User Manual page 133

24-bit digital signal processor
Table of Contents

Advertisement

Table 6-12. Host Port Control Register (HPCR) Bit Definitions (Continued)
Bit Number
Bit Name
12
HDDS
11
HMUX
10
HASP
9
HDSP
8
HROD
7
6
HEN
Reset Value
0
Host Dual Data Strobe
If the HDDS bit is cleared, the HI08 operates in single-strobe bus mode. In
this mode, the bus has a single data strobe signal for both reads and
writes. If the HDDS bit is set, the HI08 operates in dual strobe bus mode.
In this mode, the bus has two separate data strobes: one for data reads,
the other for data writes. See Figure 6-13 on page 6-21 and Figure 6-14
on page 6-21 for details on dual and single strobe modes.
0
Host Multiplexed Bus
If HMUX is set, the HI08 operates in multiplex mode, latching the lower
portion of a multiplexed address/data bus. In this mode the internal
address line values of the host registers are taken from the internal latch.
If HMUX is cleared, it indicates that the HI08 is connected to a
non-multiplexed type of bus. The values of the address lines are then
taken from the HI08-dedicated address signals.
0
Host Address Strobe Polarity
If HASP is cleared, the host address strobe (HAS) signal is an active low
input, and the address on the host address/data bus is sampled when the
HAS signal is low. If HASP is set, HAS is an active-high address strobe
input, and the address on the host address or data bus is sampled when
the HAS signal is high.
0
Host Data Strobe Polarity
If HDSP is cleared, the data strobe signals are configured as active low
inputs, and data is transferred when the data strobe is low. If HDSP is set,
the data strobe signals are configured as active high inputs, and data is
transferred when the data strobe is high. The data strobe signals are
either HDS by itself or both HRD and HWR together.
0
Host Request Open Drain
Controls the output drive of the host request signals. In the single host
request mode (that is, when HDRQ is cleared in ICR), if HROD is cleared
and host requests are enabled (that is, if HREN is set and HEN is set in
the host port control register (HPCR)), then the HREQ signal is always
driven by the HI08. If HROD is set and host requests are enabled, the
HREQ signal is an open drain output. In the double host request mode
(that is, when HDRQ is set in the ICR), if HROD is cleared and host
requests are enabled (that is, if HREN is set and HEN is set in the HPCR),
then the HTRQ and HRRQ signals are always driven. If HROD is set and
host requests are enabled, the HTRQ and HRRQ signals are open drain
outputs.
0
Reserved. Write to 0 for future compatibility.
0
Host Enable
If HEN is set, the HI08 operates as the host interface. If HEN is cleared,
the HI08 is not active, and all the HI08 signals are configured as GPIO
signals according to the value of the HDDR and HDR.
Host Interface (HI08)
DSP Core Programming Model
Description
6-19

Advertisement

Table of Contents
loading

Table of Contents