Preparations
PLC Setup
There are no settings that need to be made in the PLC Setup.
DM Area Settings
• Settings for PLS2(887) Instruction (D0 to D7)
Acceleration rate: 300 pps/4 ms
Deceleration rate: 200 pps/4 ms
Target frequency: 50,000 pps
Number of output pulses: 600,000 pulses
Starting frequency: 100 pps
Ladder Program
2960.00
Start input
Additional Information
• Absolute pulses can be specified when the origin position has been defined.
• If a target frequency that cannot be reached has been set, the target frequency will be reduced
automatically, i.e., triangular control will be performed.
CJ2M CPU Unit Pulse I/O Module User's Manual
Setting
D0
D1
D2
D3
D4
D5
D6
D7
@PLS2
← Pulse output 1
#0001
← Specifies pulse + direction output method, CW, and absolute pulses.
#0100
← Acceleration rate, deceleration rate, target frequency, number of pulses setting
D0
← Starting frequency
D6
Word
Data
#012C
#00C8
#C350
#0000
#27C0
#0009
#0064
#0000
8 Pulse Outputs
8-31
8