Cabling Procedure

The following cabling procedure uses the stacking topology in
switches in any of the stacking topologies shown in
cabling, follow these steps:
1. Connect a 40GbE port on the first switch to a 40GbE port on the second switch.
2. Connect another 40GbE port on the second switch to a 40GbE port on the third switch.
3. Connect another 40GbE port on the third switch to a 40GbE port on the fourth switch.
4. Connect another 40GbE port on the fourth switch to a 40GbE port on the first switch.
The resulting ring topology allows the entire stack to function as a single switch with resilient fail-over
capabilities. If you do not connect the last switch to the first switch (Step 4), the stack operates in a daisy
chain topology with less resiliency. Any failure in a non-edge stack unit causes a split stack.

Accessing the CLI

To configure a stack, you must access the stack master in one of the following ways:
For remote out-of-band management (OOB), enter the OOB management interface IP address into a
Telnet or secure shell (SSH) client and log in to the switch using the user ID and password to access
the CLI.
For local management, use the attached console connection to the master switch to log in to the CLI.
Console access to the stack CLI is available on the master only.
For remote in-band management from a network management station, enter the virtual local area
network (VLAN) IP address of the management port and log in to the switch to access the CLI.

Configuring and Bringing Up a Stack

After you attach the 40G QSFP or direct attach cables in a stack of MXL 10/40GbE Switches, to bring up
the stack, follow these steps.
Note: The procedure uses command examples for the stacking topology in
Step
Task
1
Set up a connection to the CLI on an MXL 10/40GbE Switch as described in
2
Log on to the CLI and enter Global Configuration mode.
Figure
31-1. Follow the same steps to cable
Supported Stacking
Topologies. To connect the
Command Syntax
Accessing the
Login: username
Password: *****
FTOS> enable
FTOS# configure
Figure
31-1.
Command Mode
CLI.
---