Stack Unit In Card-Problem State Due To Configuration Mismatch - Dell Force10 MXL Blade Configuration Manual

Configuration guide for the mxl 10/40gbe switch io module
Hide thumbs Also See for Force10 MXL Blade:
Table of Contents

Advertisement

Figure 31-20. Card Problem Error - Different FTOS Versions: Resolved
FTOS#show system brief
Stack MAC : 00:1e:c9:f1:01:57
Reload Type : normal-reload [Next boot : normal-reload]
--
Stack Info
Unit
UnitType
---------------------------------------------------------------------------------------------
----------------------------
0
Management
1
Member
2
Standby
3
Member
4
Member
5
Member

Stack Unit in Card-Problem State Due to Configuration Mismatch

Problem: A stack unit enters a Card-Problem state because there is a configuration mismatch between the
logical provisioning stored for the stack-unit number on the master switch and the newly added unit with
the same number.
Resolution: The resolution is to reload the stack. When the stack is up, the card problem will be solved
Step
Task
1
From the Master Switch, reload the entire stack
570
|
Stacking
--
Status
ReqTyp
online
online
MXL-10/40GbE
online
MXL-10/40GbE
not present
not present
not present
CurTyp
MXL-10/40GbE
MXL-10/40GbE
MXL-10/40GbE
MXL-10/40GbE
Command Syntax
reload
Version
Ports
8-3-16-79
56
8-3-16-79
56
8-3-16-79
56
Command Mode
EXEC Privilege

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents