Set the RMON Alarm

To set an alarm on any MIB object, use the
CONFIGURATION mode. To disable the alarm, use the
Command Syntax
[no] rmon alarm number variable interval
{delta | absolute} rising-threshold [value
event-number] falling-threshold value
event-number [owner string]
or
[no] rmon hc-alarm number variable interval
{delta | absolute} rising-threshold value
event-number falling-threshold value
event-number [owner string]
or
rmon alarm
rmon hc-alarm
no
Command Mode
Purpose
CONFIGURATION
Set an alarm on any MIB object. Use the
this command to disable the alarm.
Configure the alarm using the following optional
parameters:
command in GLOBAL
form of these commands:
number: Alarm number, must be an integer from
1 to 65,535, the value must be unique in the
RMON alarm table.
variable: The MIB object to monitor—the
variable must be in the SNMP OID format. For
example, 1.3.6.1.2.1.1.3. The object type must be
a 32-bit integer for the
rmon alarm
64 bits for the
rmon hc-alarm
interval: Time in seconds the alarm monitors the
MIB variable, the value must be between 5 to
3,600.
: Tests the change between MIB variables,
delta
this is the alarmSampleType in the RMON alarm
table.
: Tests each MIB variable directly, this is
absolute
the alarmSampleType in the RMON alarm table.
value: Value at which the
rising-threshold
rising-threshold alarm is triggered or reset. For
the
rmon alarm
command, this is a 32-bits value,
for
command, this is a 64-bits
rmon hc-alarm
value.
event-number: Event number to trigger when the
rising threshold exceeds its limit. This value is
identical to the alarmRisingEventIndex in the
alarmTable of the RMON MIB. If there is no
corresponding rising-threshold event, the value
should be zero.
falling-threshold
value: Value at which the
falling-threshold alarm is triggered or reset. For
the
command, this is a 32-bits value,
rmon alarm
for
rmon hc-alarm
command, this is a 64bits
value.
event-number: Event number to trigger when the
falling threshold exceeds its limit. This value is
identical to the alarmFallingEventIndex in the
alarmTable of the RMON MIB. If there is no
corresponding falling-threshold event, the value
should be zero.
string: (Optional) Specifies an owner for
owner
the alarm, this is the alarmOwner object in the
alarmTable of the RMON MIB. Default is a
null-terminated string.
Remote Monitoring (RMON) | 455
no
form of
command and
command.