Master Switch Recovers From Failure; Stack Unit In Card-Problem State Due To Incorrect Ftos Version - Dell Force10 MXL Blade Configuration Manual

Configuration guide for the mxl 10/40gbe switch io module
Hide thumbs Also See for Force10 MXL Blade:
Table of Contents

Advertisement

Master Switch Recovers from Failure

Problem: The master switch recovers from a failure after a reboot and rejoins the stack:
As a member unit if there is already a standby
As a standby if there is no standby in the stack
Protocol and control plane recovery requires time before the switch is fully online.
Resolution: When the entire stack is reloaded, the recovered master switch becomes the master unit of the
stack.

Stack Unit in Card-Problem State Due to Incorrect FTOS Version

Problem: A stack unit enters a Card-Problem state because the switch has a different FTOS version than
the master unit
(Figure
31-19). The switch does not come online as a stack unit.
Resolution: To restore a stack unit with an incorrect FTOS version as a member unit, disconnect the
stacking cables on the switch and install the correct FTOS version. Then add the switch to the stack as
described in
Adding a Stack
back online, use the
show system brief
Figure 31-19. Card Problem Error - Different FTOS Versions
FTOS#show system brief
Stack MAC : 00:1e:c9:f1:01:57
Reload Type : normal-reload [Next boot : normal-reload]
--
Stack Info
--
Unit
UnitType
Status
----------------------------------------------------------------------------------------------
---------------------------
0
Management
online
1
Member
card problem
2
Standby
online
3
Member
not present
4
Member
not present
5
Member
not present
Unit. To verify that the problem has been resolved and the stacked switch is
command
(Figure
ReqTyp
MXL-10/40GbE
MXL-10/40GbE
MXL-10/40GbE
31-20).
CurTyp
MXL-10/40GbE
unknown
56
MXL-10/40GbE
8-3-16-79
Version
Ports
8-3-16-79
56
56
Stacking | 569