EMS Messages
Effect. No printing occurs, the Spooler job is requeued, and the Spooler device is
placed offline.
Recovery. If the wrong FASTCNFG or FASTKCON file is used, correct the
FASTCNFG= parameter in the higher-level FASTCNFG file.
If a FASTCNFG file does not exist (error 11), create one.
For error 12 (file in use), make sure the FASTCNFG file is not in use by EDIT or
another process.
For error 48, adjust the file security or restart the Spooler from another user ID.
After the configuration file access is corrected, restart the Spooler device. (Depending
on the device configuration, the device might restart automatically.)
512
proc-num DEV: device-name Cannot OPEN Define define-name,
Error file-err, File cnfg-file
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
define-name
is either =FASTKCON or =FASTCNFG.
file-err
is the file-system error returned. See the Guardian Procedure Errors and
Messages Manual for explanations of file-system errors.
cnfg-file
is the name of the FASTCNFG or FASTKCON file specified in the ADD DEFINE.
Cause. The specified FASTCNFG or FASTKCON file could not be opened due to a
file-system error.
Effect. No printing occurs, the Spooler job is requeued, and the Spooler device is
placed offline.
Recovery. If the wrong FASTCNFG or FASTKCON file is used, either correct the
DEFINE statement and restart the Spooler or correct the FASTCNFG= parameter in
the higher level FASTCNFG file.
If a FASTCNFG file does not exist (error 11), create one.
Spooler FASTP Network Print Processes Manual — 427528-006
B - 64
FASTP EMS 512 Text Messages