Hp smart update firmware dvd user guide (47 pages)
Summary of Contents for HP Spooler FASTP
Page 1
This manual describes the Spooler FASTP network print processes: FASTPTCP, FASTPSMB, FASTPNOV, FASTPX25, and FASTPXNS. The FASTP network print processes allow you to use the Spooler to print documents on printers attached to HP NonStop™ systems through TCP/IP LANs, SMB LANs, Netware LANs, X.25 WANs, and XNS LANs.
Page 2
Document History Part Number Product Version Published 422025-001 May 2000 427528-001 November 2000 427528-002 May 2002 427528-003 December 2002 427528-004 September 2005 427528-006 February 2013...
Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
What’s New in This Manual Manual Information New and Changed Information About This Manual Related Manuals Notation Conventions 1. Overview of Spooler FASTP Network Print Processes FASTP Network Print Process Environment Spooler Environment IOP Environment Control Operations and Job Information Trace Facility EMS Event and 512 Messages 2.
Page 6
3-21 FASTCNFG DEVICE Attributes for Supported TTAP Printers Connected Through AWAN Servers or Other TELNET Terminal Servers 3-23 FASTCNFG DEVICE Attributes for HP JetDirect Printers 3-26 FASTCNFG POLLTYPE Keyword for HP JetDirect Printers 3-28 FASTCNFG DEVICE Attributes for Lexmark Printers...
Where to Find Information About NetWare Error Messages 5-15 6. Installation and Configuration Considerations for FASTPX25 Installation Requirements Printer Installation and X25AM Configuration Considerations PAD Considerations X25AM Line Configuration Considerations X25AM Subdevice Configuration Considerations X.25 NUA and SVC Considerations Spooler FASTP Network Print Processes Manual—427528-006...
Page 8
Where to Find Information About XNS Error Messages 7-24 8. Troubleshooting and Using the Trace Facility Troubleshooting and Reporting Problems Using the Trace Facility Creating Trace Files Configuring the Shadow Trace File Names in the FASTCNFG File Spooler FASTP Network Print Processes Manual—427528-006...
Page 9
Example 3-2. Sample FASTCFG File for a TTAP Printer Connected Through a TELNET Terminal Server 3-25 Example 3-3. Sample FASTCFG File for an HP JetDirect Printer 3-31 Example 3-4. Sample FASTCFG File for Printer Connected Through a Microplex Server 3-35 Example 3-5.
Page 10
Table 4-2. Spooler Device Attributes With Special Effects on SMB Print Queues Table 4-3. Examples of Subdevice Names Used as RESOURCE Names Table 4-4. HP Device Types and Default Data-Block Sizes 4-10 Table 4-5. Examples of Originator Text 4-12 Table 4-6.
Page 11
7-21 Table 8-1. Common FASTP Network Print Process Identifier Records and Data Records Table 8-2. FASTPTCP Identifier Records and Data Records Table A-1. Specifying 7-Bit-Mode and 8-Bit-Mode Language Set Table A-2. National-Use Character Substitution Spooler FASTP Network Print Processes Manual—427528-006...
This manual describes the Spooler FASTP network print processes: FASTPTCP, FASTPSMB, FASTPNOV, FASTPX25, and FASTPXNS. The FASTP network print processes allow you to use the Spooler to print documents on printers attached to HP NonStop™ systems through TCP/IP LANs, SMB LANs, Netware LANs, X.25 WANs, and XNS LANs.
Page 14
7-3 for H-series RVUs. Added DATA=filename attribute and incorporated it into the syntax statement under Reading an Unstructured Shadow Trace File on page 8-9. Added new event messages to Appendix B, EMS Messages. Spooler FASTP Network Print Processes Manual — 427528-006...
Spooler Utilities Reference Manual. The FASTP network print processes are enhanced versions of FASTP that allow you to use the Spooler to print documents on printers attached to HP NonStop systems through HP NonStop TCP/IP local area networks (LANs), SMB LANs, Netware LANs, X.25 WANs, and XNS LANs.
Related Manuals Related Manuals For more detailed information about the Spooler and the network data communications products, you must consult the appropriate HP NonStop manuals. For more information about the Spooler, consult the following manuals: Spooler Utilities Reference Manual ...
Page 17
CALL STEPMOM ( process-id ) ; If there is no space between two items, spaces are not permitted. In the following example, there are no spaces permitted between the period and any other items: $process-name.#su-name Spooler FASTP Network Print Processes Manual — 427528-006...
Bold Text. Bold text in an example indicates user input entered at the terminal. For example: ENTER RUN CODE ?123 CODE RECEIVED: 123.00 The user must press the Return key after typing the input. Spooler FASTP Network Print Processes Manual — 427528-006 viii...
Page 19
% Percent Sign. A percent sign precedes a number that is not in decimal notation. The %þ notation precedes an octal number. The %Bþ notation precedes a binary number. The %Hþ notation precedes a hexadecimal number. For example: %005400 P=%p-register E=%e-register Spooler FASTP Network Print Processes Manual — 427528-006...
Common Run-Time Environment (CRE). The CRE has many new message types and some new message type codes for old message types. In the CRE, the message type SYSTEM includes all messages except LOGICAL-CLOSE and LOGICAL-OPEN. Spooler FASTP Network Print Processes Manual — 427528-006...
Spooler and IOP environments, and discusses FASTP network print process support for printer-control operations, Spooler job and batch job subcommands, the trace facility, and EMS messages. Spooler FASTP Network Print Processes Manual — 427528-006 1 - 1...
Figure 1-1. FASTP Network Print Process Components HP NonStop System Spooler Subsystem FASTPxxx Print Process FASTCNFG File User's LAN or WAN Printer Print Server vst001.vsd Spooler FASTP Network Print Processes Manual — 427528-006 1 - 2...
Page 23
Guide (for G-series systems) or the Guardian System Operations Guide (for D-series systems), and the Spooler Utilities Reference Manual. For more information about the IOP environments, refer to the HP NonStop publication manuals related to the specific IOP environment you are using.
The Spooler subsystem is a set of utilities that form an interface between you (and your application programs) and the print devices of an HP NonStop system. Instead of directing application output directly to a printer, the Spooler allows you to store the output as jobs in a disk file, and then peruse or queue the output to be sent to a designated printer when it becomes available for printing.
ASCII 512 text messages can be generated instead of the event messages by setting bit 15 (%1) in the Spoolcom PRINT PARM command. All of these messages are now described in Appendix B, EMS Messages. Spooler FASTP Network Print Processes Manual — 427528-006 1 - 5...
4. Configuration of one or more job locations in the Spooler environment to represent each printer associated with the FASTP network print process and to associate the printer with the Spooler device name (by using the Spoolcom LOC command). Spooler FASTP Network Print Processes Manual — 427528-006 2 - 1...
For either a G-series system or a D-series system, each FASTP network print process product includes the object code for its print process. The software for a FASTP network print process is supplied as a distribution subvolume (DSV). Spooler FASTP Network Print Processes Manual — 427528-006 2 - 2...
Note. For FASTPTCP only, in addition to the placement of the FASTPTCP object file in the $SYSTEM.SYSTEM subvolume, the SHAP object file is placed in the $dsv.ZTCPPRT subvolume, and the FASTKCUT object file is placed in the $SYSTEM.SYSTEM subvolume. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 3...
FASTCNFG files into a FASTKCON key-sequenced file. Using this feature is described in detail in Creating a FASTKCON Configuration File (Beginning with the G06 and D48 RVUs) on page 3-40. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 4...
The FASTP network print process name is the process name which is used by the Spooler to represent the print process. The process name is assigned in a Spoolcom PRINT command. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 5...
Page 32
The device-name format can vary based on which FASTP network print process you are configuring. The device name must always be specified in a Spoolcom DEV command. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 6...
In most cases, the effect of DEVRESET is the same as that of any other Spooler printer, however support for DEVRESET can vary based on the specific FASTP network print process being implemented. See the product-specific sections of this manual for exceptions. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 7...
Page 34
LUEOLWHEN is the same as that of any other Spooler printer, however support for LUEOLWHEN can vary based on the specific FASTP network print process being implemented. See the product-specific sections of this manual for exceptions. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 8...
Page 35
Specifies the number of seconds a print process waits before retrying an I/O operation that has failed because of a retryable I/O error. The effect of RETRY is the same as that of any other Spooler printer. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 9...
Page 36
WIDTH is the same as that of any other Spooler printer. XREF Produces a cross-reference list of devices, locations, and print processes. The effect of XREF is the same as that of any other Spooler printer. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 10...
For 5573 and 5577 printers, adds a form feed after line 66 if SETMODE 5 0 0 has been issued and no form feed or CONTROL 1 0 is encountered. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 11...
Page 38
If this bit is not set, header and trailer pages are printed outside the scope of the FONT jobs. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 12...
Designating Spooler Job Locations A Spooler job location associates a printer with the Spooler device name. Spooler job locations are specified in a Spoolcom LOC command. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 13...
Page 40
2. Create a print process using the print process object code. For example: PRINT $PRNT1, FILE $SYSTEM.SYSTEM.FASTPSMB, BACKUP 2 where $PRNT1 is the process name to be assigned to the print process. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 14...
Page 41
2-11 and the product-specific sections of this manual. For details about how to calculate the DEV PARM value, see Calculating the Value of the PARM Attributes on page 2-13. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 15...
Page 42
FASTPSMB print process. The FASTPSMB print process is instructed to read the FASTCNFG file. Specification of a Spooler job location named #LAN1 with the Spooler device name. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 16...
FASTCNFG file that shows the configuration of an AWAN device for a FASTPTCP process. The remainder of this subsection describes how to create a FASTCNFG file. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 17...
TACL DEFINE commands), and this file can redirect a specific FASTP network print process to subordinate files. For more information about FASTCNFG file redirection, including the syntax for the FASTCNFG attribute, see FASTCNFG Attribute on page 2-25. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 18...
Page 45
If EXCLUSIVE ON is specified, the print process opens the device once and keeps it open (that is, the print process does not open and close the device). Therefore, to ensure that an altered FASTCNFG file is read, perform the following: Spooler FASTP Network Print Processes Manual — 427528-006 2 - 19...
Page 46
A FASTCNFG file also must follow the following file formatting rules. File-Formatting Rules Table 2-6 summarizes the file-formatting rules for a FASTCNFG file. These rules are discussed in greater detail in the subsections that follow the table. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 20...
For example: !This is legal! SERVER = server-name !This is legal!SERVER = server-name !This is legal SERVER = server-name !This is not legal SERVER = server-name Spooler FASTP Network Print Processes Manual — 427528-006 2 - 21...
Page 48
FASTPTCP and FASTPX25, support additional keywords that apply only to their environment. Those keywords are described in the product-specific sections of this manual to which they apply. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 22...
PROCESS keyword is encountered. Note that when a FASTCNFG file is converted to a FASTKCON file, any PROCESS keywords specified in the FASTCNFG file are ignored by the FASTKCUT utility. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 23...
Page 50
The device being described is the device represented by the name $PRT. The communications protocol is NetBios. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 24...
Page 51
(this FASTCNFG file would be a level-3 file): PROCESS $process-name FASTCNFG = [\node.][$volume.][subvolume.]filename Specify device attributes for specific devices: DEVICE [\node.]$device-name[.#qualifier] attribute = attribute-value [,attribute = attribute-value]... Spooler FASTP Network Print Processes Manual — 427528-006 2 - 25...
Param = 16 through 79 Issue <parameter-16> line feeds. If required (by a SETMODE function) a form feed can be substituted for one of the line feeds. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 27...
%33,"&a68r142c142L"; ! Posn - Row 68 Col 142 Left Margn 142 ?CONTROLBUF 103 ! Top of Form Substitute %33,"&a6L",%14,%15; ! Left Margin 6, FF CR ?END-FONT ?START-LOCATIONS #LISTING.DEFAULT LPX8D $LP2 Spooler FASTP Network Print Processes Manual — 427528-006 2 - 29...
Page 56
FASTP network print process to treat the device like type (5,7) when CHARMAP JISKANJIKANA is selected, the buffer parameter must contain the two-byte string <28, 46>. The syntax of CONTROLBUF 111 is: CONTROLBUF 111 buffer; where Spooler FASTP Network Print Processes Manual — 427528-006 2 - 30...
"This is font job data for pink and red jobs" "This is font job data for pink and red jobs" ?END-FONT ?START-LOCATIONS #LASER.BLUE COLORGROUP1 $LASER.#A #LASER.PINK COLORGROUP1 $LASER.#A #LASER.RED COLORGROUP1 $LASER.#A Spooler FASTP Network Print Processes Manual — 427528-006 2 - 31...
The current second as a 2-digit number (for example, 59). The current minute as a 2-digit number (for example, 05). The current hour as a 2-digit number (for example, 23). Spooler FASTP Network Print Processes Manual — 427528-006 2 - 32...
Page 59
The group (first 8 characters) portion of the Spooler LOCATION name. The second 8 characters of the Spooler REPORT name. The first 8 characters of the Spooler REPORT name. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 33...
Page 60
"Company" expanded and centered on the first line; the date expanded and centered on the second line; and data extracted from a file using the user ID as the key expanded on the third line. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 34...
Shared, Read access; there is no need to wait for the FASTP network print process to close the data file(s) to add or change entries. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 35...
= 0 Use postspace mode; line-spacing commands follow the print data. This is the default value. = 1 Use prespace mode; line-spacing commands precede the print data. The line-spacing commands are determined by SETMODE 6. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 36...
Page 63
PostScript job and adds suitable line breaks at the record boundaries. If the FASTP network print process finds line breaks in the data, it assumes a Binary PostScript job. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 37...
Places the job in the hold state. The effect of HOLD is the same as that of any other Spooler printer within the Spooler subsystem. This parameter is not transmitted to the print process. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 38...
Note that some BATCH subcommands have special considerations when used with a specific version of the FASTP network print process. These considerations are described in the product-specific sections of this manual. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 39...
FASTP network print process being implemented. See the product-specific sections of this manual for any special considerations that might apply. This parameter is not transmitted to the print process. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 40...
(such as, a device down error). This situation requires operator intervention to recover unless the Spooler RESTART parameter has been specified as non-zero in the Spoolcom DEV command when configuring the device. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 41...
Unless the SAVEABEND option has been disabled in the BIND, an abend always creates a SAVEABEND file. SAVEABEND dumps generally indicate a serious problem and should be forwarded to your service provider for analysis. Spooler FASTP Network Print Processes Manual — 427528-006 2 - 42...
Considerations for FASTPTCP The FASTPTCP print process allows you to use the Spooler to print documents on printers attached to HP NonStop systems through HP NonStop TCP/IP networks either directly or through TELNET terminal servers. FASTPTCP supports printers attached in the following ways: ...
Page 70
FASTCNFG DEVICE, HOSTS, and POLLTYPE Configuration for FASTPTCP Creating a FASTKCON Configuration File (Beginning with the G06 and D48 RVUs) Spooler FONT Job Considerations for LPD Connections Spooler FASTP Network Print Processes Manual — 427528-006 3 - 2...
In general, TTAP printers are handled like other printers, but require the character size to be 8 bits, even parity, and no flow control at the asynchronous port. Note. This discussion excludes the protocols supported by HP JetDirect, Lexmark, Microplex, and LPD print servers. For information about these protocols, refer to the following subsections: ...
3884, and 3885 models immediately discard any unsent data queued to the asynchronous port. A similar loss of data can occur if the AWAN 3883, 3884, and 3885 models are not properly configured as PORT TYPE HARDCOPY. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 5...
5577 with the TTAP protocol. The printers are connected to an AWAN server or other terminal server asynchronous port by using the following settings: 8-bit character length and EVEN parity. Binary or transparent 8-bit data. No flow control. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 6...
3-40. SHAP is described in detail in Reading an Unstructured Shadow Trace File on page 8-9. Beginning with the G06.10 and D48.02 RVUs, FASTPTCP supports the following new configuration options: Spooler FASTP Network Print Processes Manual — 427528-006 3 - 7...
Page 76
In addition, note that the use of bit 2 (%20000) of the Spoolcom DEV PARM attribute can be set for the HP JetDirect protocols to cause all SNMP responses to be logged to Spooler FASTP Network Print Processes Manual — 427528-006...
FASTPTCP, including the use of the DEFAULT, HOSTS, and POLLTYPE keywords, and FASTCNFG DEVICE configuration attributes for TCP/IP printers are discussed in FASTCNFG DEVICE, HOSTS, and POLLTYPE Configuration for FASTPTCP on page 3-13. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 9...
FASTPTCP process. Note that the PRINT PARM attribute is a 16-bit mask; for a description of how to calculate the value of a bit mask, see Calculating the Value of the PARM Attributes on page 2-13. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 10...
Table 2-3, Spooler Device Attributes and Their Effect on FASTP Network Printers, on page 2-7. Table 3-2 lists the Spooler device attributes that have special considerations for FASTPTCP and describes their effect on TCP/IP printers. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 11...
For 5573, 5573D, 5574, and 5577 printers, set bit 9 (%100) if landscape header pages are required. For 5577 printers, set bit 9 (%100) for offset job output. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 12...
Using the HOSTS Keyword Entry on page 3-14. The FASTCNFG POLLTYPE keyword, which can be used with HP JetDirect printers to define a POLLTYPE record to control interpretation of SNMP responses. Essentially, this feature allows you to determine whether FASTPTCP performs MIB-II SysUpTime processing and how FASTPTCP maps SNMP printer responses to Guardian file error codes and, optionally, EMS operator messages.
Page 84
The values are: TCP/IP Use for direct TCP/IP connections to an HP JetDirect card, a Lexmark card, a Microplex server, an LPD server, and for terminal servers that do not support TELNET. TCP/IP is the default value.
Page 85
FASTPTCP detects the DEVTYPE value and uses the TAP protocol. HPJETDIRECT Use for HP JetDirect connections. The SNMP agent on the card is queried to determine job status. LEXMARK Use with the laser printer models 5576/78 and other Lexmark printers supporting the job completion protocol.
Page 86
KEEPALIVE = YES | NO Default NO. If YES, activates TCP socket keepalive. This attribute is rarely needed, but might be useful for an HP external print server with extended stacker full condition. SHADOW[n] = shadow-file-namen...
Page 87
TELNET Terminal Servers and End of Print Job Considerations on page 3-5. For PROTOCOL NONE, HPJETDIRECT, and MICROPLEX, the attribute SHUTDOWNTO is recommended, with a value greater than or equal to, the value of the TIMEOUT attribute. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 19...
Spooler supervisor that the job is complete. Values can be up to 12000 (2 minutes). The SLOWPACE specification is optional and can adversely affect performance so use it with caution. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 20...
TCP/IP socket-session connection differently. For a more detailed discussion of this parameter and its effect on TELNET terminal servers, see TELNET Terminal Servers and End of Print Job Considerations on page 3-5. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 21...
Page 90
SLOWPACE can prevent jobs from being lost, while allowing devices to be set as EXCLUSIVE OFF in Spoolcom. The use of SLOWPACE is generally not recommended; its purpose has largely been superseded by NOTIMINGMARK=NO for AWAN and by SHUTDOWNTO. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 22...
The print process and the Spooler use the protocol (originally an asynchronous-line protocol) to guarantee job delivery. TTAP and TAP printers can be connected to AWAN servers or other terminal servers supporting the TELNET protocol. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 23...
Page 92
Note that SLOWPACE is not recommended with TTAP printers. POLLINT = interval specifies the time (in 10-millisecond units) that FASTPTCP should wait between successive polls to clear device busy. The default value is 800 (8 seconds). Spooler FASTP Network Print Processes Manual — 427528-006 3 - 24...
SNMP community name. In these cases, the SNMP community name must be configured at the HP JetDirect interface to the value “public” or some other value that matches the value specified in the FASTCNFG file. Refer to the HP JetDirect documentation for details.
Page 95
Only change the SHUTDOWNTO value when you are advised to do so by support staff to resolve a specific problem. Note. SHUTDOWNTO only applies to the G06.10 and D48.02 RVUs and later. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 27...
FASTCNFG POLLTYPE Keyword for HP JetDirect Printers Beginning with the G06.10 and D48.02 RVUs, in addition to the DEVICE, DEFAULT, and HOSTS keywords, each FASTPTCP FASTCNFG file for HP JetDirect printers can optionally contain a POLLTYPE keyword entry. The POLLTYPE entry defines a POLLTYPE record to control interpretation of SNMP responses.
Page 97
Only the following values can be specified and they are interpreted as follows: feok Signals the Spooler supervisor that the job completed printing normally. feinuse Same as above. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 29...
Page 98
Guardian file code and optionally an EMS message to be used if no RESPONSE values match the printer response. The fecode and EMS parameters have the same meanings for OTHERWISE as they do for RESPONSE. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 30...
OTHERWISE =102,EMS Sample FASTCNFG File for an HP JetDirect Printer Example 3-3 contains a sample FASTCNFG file for an HP JetDirect printer: Example 3-3. Sample FASTCFG File for an HP JetDirect Printer DEVICE $HERON ! 5577 equipped with HP JetDirect card...
The default name is public. POLLINT = interval specifies the time (in 10-millisecond units) that FASTPTCP should wait at end-of- job to detect printing completion. The default value is 200 (2 seconds). Spooler FASTP Network Print Processes Manual — 427528-006 3 - 32...
Page 101
FASTPTCP queries the SNMP agent and retries, if appropriate, POLLNUM times. For customers whose average print job is longer than 200 pages, WAITTIME should be increased. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 33...
FASTPTCP marks the print job as complete to the Spooler. Use BOTH if many short jobs are sent in a group. Also see WAITTIME. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 34...
Configuring FASTPTCP for LPDs using RFC 1179 can be a complex task. The RFC defines many potential attributes, and because implementations can differ, no single FASTCNFG template can satisfy all conditions. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 35...
Page 104
Most LPD servers require that the FASTPTCP DEVICE QUEUENAME attribute be pre- configured at the LPD server. In rare cases, the FASTPTCP DEVICE HOSTNAME attribute or the IP address of the HP server must also be pre-configured at the LPD server.
Page 105
FASTPTCP attempts to use them as needed. However, if you want to restrict FASTPTCP to a specific port, the SOURCEPORT attribute can be included. Or, if you want to specify an alternate (and possibly larger) range of ports Spooler FASTP Network Print Processes Manual — 427528-006 3 - 37...
Page 106
FASTCNFG file. Note. Implementations of LPD servers vary in their support of these options. The following LPD job-information attributes can be specified in the FASTCNFG file for an LPD connection: Spooler FASTP Network Print Processes Manual — 427528-006 3 - 38...
Page 107
LPD server. The default value is YES, which causes the print file to be deleted after printing on the LPD server. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 39...
FASTKCON format by using the FASTKCUT utility. FASTKCON does not change the FASTCNFG device-parameter syntax or interpretation. The original FASTCNFG files are still supported if FASTKCON is not present. POLLTYPE requires FASTKCON Spooler FASTP Network Print Processes Manual — 427528-006 3 - 40...
(such as DEVICE, SPOOLER, PROCESS, FASTCNFG, MACRO, HOSTS, POLLTYPE, or another DEFAULT keyword). If no attribute definitions appear before the next FASTCNFG keyword is encountered, no default values are in effect. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 41...
FASTKCUT commands described below. If no command is specified, FASTKCUT displays a help screen listing the command syntax for all the supported FASTKCUT commands. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 45...
Page 114
EMS log, and the device would be delayed for the Spoolcom DEV RESTART interval. After FASTKCUT has written a device record, any FASTPTCP process can access the record freely. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 46...
Page 115
If kcon-file does not exist, it will be created as a new FASTKCON file. The UPDATE command can have a slight impact on printer operation. When an existing record is updated, it is locked by the file system until the update is Spooler FASTP Network Print Processes Manual — 427528-006 3 - 47...
Page 116
$SYSTEM.SYSTEM.FASTKCON, an asterisk (*) can be used in place of the complete file name. The LIST command has no impact on printer operation because no changes are made to the FASTKCON file and no records are locked. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 48...
When multiple FASTCNFG files are to be converted into a single FASTKCON file, such as when level-2 or level-3 FASTCNFG files are used, you use a combination of the Spooler FASTP Network Print Processes Manual — 427528-006 3 - 49...
Key Length 48 bytes Record Length 4000 bytes Record Layout Bytes 0-47 Name field. For DEVICE records, specifies the name in uppercase ASCII, left-justified, blank filled. For POLLTYPE records, specifies Spooler FASTP Network Print Processes Manual — 427528-006 3 - 50...
Page 119
<pad-byte> is an additional byte of binary zero. This byte is only used if needed to force an even byte length. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 51...
DEFAULT or DEVICE command. FASTKCUT Messages FASTKCUT generates messages during normal operation and also when errors are detected. These messages are self-explanatory and are prefixed by a Knn message code. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 52...
JOBNAME specified in the FASTCNFG file. user ID FASTPTCP uses the new user ID specified in the P - User identification command. This user ID replaces any USERID specified in the FASTCNFG file. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 53...
Page 122
4 - troff S font command. FASTPTCP uses the first word of the buffer as the count in the indent count I - Indent Printing command. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 54...
LPDs that do not recognize the o - Print PostScript output file command but can cope with receiving PostScript data. Default FASTPTCP emits the f - Print formatted file command. Spooler FASTP Network Print Processes Manual — 427528-006 3 - 55...
Note. The information in this section applies to D- and G-series RVUs only. The FASTPSMB print process allows you to use the Spooler to print documents on printers attached to HP NonStop systems through an SMB LAN print server. The FASTPSMB print process uses the following communications standards: ...
For additional information about the installation and configuration of TLAM, NBT or NBX, including any LAN requirements, consult the following manuals: TLAM Configuration and Management Manual (for D-series systems only) NBT Manual NBX Manual Spooler FASTP Network Print Processes Manual — 427528-006 4 - 2...
The creation of a FASTCNFG file is discussed in general terms in Configuring a FASTCNFG File on page 2-17. FASTCNFG DEVICE attributes for SMB LAN print queues are discussed in FASTCNFG DEVICE Configuration for FASTPSMB on page 4-5. Spooler FASTP Network Print Processes Manual — 427528-006 4 - 3...
If a device subtype is not specified, the default printer subtype is LU1. Table 4-1. FASTPSMB Device Type and Subtype Information Printer Type Device Type Device Subtype 5512 5515 5516 5518 5573 5574 5577 Spooler FASTP Network Print Processes Manual — 427528-006 4 - 4...
For a complete discussion about the use and creation of the FASTCNFG file, see Configuring a FASTCNFG File on page 2-17. The syntax of a DEVICE entry for an SMB LAN print queue is as follows: Spooler FASTP Network Print Processes Manual — 427528-006 4 - 5...
Page 131
SMBNETBIOS. It is not case sensitive. LAN = [\node.]$lan-name specifies the name of the line or process connecting the NetBIOS LAN to the HP host. The lan-name is either the name of the NBT or NBX process, or, for ...
Table 4-3. Examples of Subdevice Names Used as RESOURCE Names Object Network Line Type Name Name Subdevice Name Fully Qualified Name DOMAIN \NODE $LINE #DM001 \NODE.$LINE.#DM001 GATEWAY \NODE $LINE #GW001 \NODE.$LINE.#GW001 POOL \NODE $LINE #GW001.POOL1 \NODE.$LINE.#GW001.POOL1 Spooler FASTP Network Print Processes Manual — 427528-006 4 - 8...
If you know that the SMB LAN print queue corresponds to an HP device type, you can use the Spoolcom DEV command (the command used to define a Spooler device name for the LAN print queue) to specify the device type. The...
Installation, Configuration, and Usage Optional DEVICE Attributes for FASTPSMB Considerations for FASTPSMB Table 4-4 summarizes the HP device types and their default data-block sizes. Table 4-4. HP Device Types and Default Data-Block Sizes Device Type Default Data-Block Size 5512 5515/5516/5518...
Page 135
Spooler job owner assigned to the job. The job owner defaults to the job owners group number and user number. substitution-text allows you to specify the string contents. Spooler FASTP Network Print Processes Manual — 427528-006 4 - 11...
The PASSWORD specification is optional. If the PASSWORD attribute is not specified, the password defaults to the NULL value (that is, the first byte is zero). Table 4-6 summarizes valid and invalid uses of the NULL value password. Spooler FASTP Network Print Processes Manual — 427528-006 4 - 12...
I/O operation to be a failure. The TIMEOUT specification is optional. The default value is 0, which causes FASTPSMB to wait indefinitely or until the I/O process for the device declares the operation a failure. Spooler FASTP Network Print Processes Manual — 427528-006 4 - 13...
Page 138
This password is used by the FASTPSMB print process (in conjunction with the account name) when it establishes a NetBIOS session with the SMB print- server application. This attribute value is case sensitive. Spooler FASTP Network Print Processes Manual — 427528-006 4 - 14...
Password encryption is not available for any other user IDs. Where to Find Information About NetBIOS and SMB Error Messages The NetBIOS and SMB error messages generated by HP products and other vendors LAN components are standardized. For information about these messages, consult the following manuals: ...
Page 140
Installation, Configuration, and Usage Where to Find Information About NetBIOS and SMB Considerations for FASTPSMB Error Messages Spooler FASTP Network Print Processes Manual — 427528-006 4 - 16...
Session Considerations NetWare LAN Considerations such as password options, control of NetWare print jobs, and unsupported NetWare print job attributes. Where to Find Information About NetWare Error Messages Spooler FASTP Network Print Processes Manual — 427528-006 5 - 1...
Your LAN must be installed and appropriately connected to your host system. For additional information about the installation and configuration of NonStop IPX/SPX, including any LAN requirements, consult the IPX/SPX Configuration and Management Manual. Spooler FASTP Network Print Processes Manual — 427528-006 5 - 2...
The creation of a FASTCNFG file is discussed in general terms in Configuring a FASTCNFG File on page 2-17. FASTCNFG DEVICE attributes for NetWare print queues are discussed in FASTCNFG DEVICE Configuration for FASTPNOV on page 5-6. Spooler FASTP Network Print Processes Manual — 427528-006 5 - 3...
IPXPROTO process (the transport process for HP NonStop IPX/SPX that connects the NetWare LAN using the print queue to an HP NonStop system). A device name consists of a dollar sign ($) followed by one to seven alphanumeric characters;...
For a complete discussion about the use and creation of the FASTCNFG file, see Configuring a FASTCNFG File on page 2-17. The syntax of a DEVICE entry for a NetWare print queue is as follows: Spooler FASTP Network Print Processes Manual — 427528-006 5 - 6...
Page 147
ID defined with the USERID attribute. The length of the password can be from 1 to 20 characters. The PASSWORD specification is mandatory. Spooler FASTP Network Print Processes Manual — 427528-006 5 - 7...
The effect of the REPORT subcommand is the same as for any other Spooler printer. The REPORT string also is part of the Job Description field for NetWare print jobs. Spooler FASTP Network Print Processes Manual — 427528-006 5 - 10...
The effect of the REPORT subcommand is the same as for any other Spooler printer. The REPORT string also is part of the Job Description field for NetWare print jobs. Spooler FASTP Network Print Processes Manual — 427528-006 5 - 11...
ID (USERID attribute) and password (PASSWORD attribute). These attributes are defined in the DEVICE entry in the FASTCNFG configuration file and must also be defined for the corresponding NetWare print server. Spooler FASTP Network Print Processes Manual — 427528-006 5 - 12...
SYSTEM field (8 characters) is the system name for the HP NonStop system where the FASTPNOV print process is located. The first character of a system name is a backslash (\). If the system name consists of fewer than 8 characters, the remaining characters in the field are blank.
In addition, supervisors and operators have complete control of the following NetWare print job attributes: Banner File Banner Name Defer Printing File Contents Form Job Description Number of Copies Spooler FASTP Network Print Processes Manual — 427528-006 5 - 14...
Tabs Where to Find Information About NetWare Error Messages The NetWare error messages generated by HP products and other vendors LAN components are standardized. For information about these messages, consult the vendor documentation and textbooks available to the general public.
Page 156
Installation, Configuration, and Usage Where to Find Information About NetWare Error Considerations for FASTPNOV Messages Spooler FASTP Network Print Processes Manual — 427528-006 5 - 16...
Note. The X.25 WAN Print Spooler should work with any PAD-attached printer that can be locally connected as a DTE device. However, HP cannot guarantee compliance with every PAD and printer. Therefore, you are advised to try the printer/PAD/network combination before committing to the use of this product.
X25AM on D-series systems, including related system software requirements, consult the following manuals System Generation Manual for X25AM SCF Reference Manual for X25AM Dynamic System Configuration (DSC) Manual Spooler FASTP Network Print Processes Manual — 427528-006 6 - 2...
WIDTH. If RECSIZE is smaller than WIDTH, more than one I/O buffer is required to send a line. Conversely, if RECSIZE is larger than WIDTH, more than one text line can be sent at a time. Spooler FASTP Network Print Processes Manual — 427528-006 6 - 4...
Page 161
The X25AM subdevice also must be configured as a device in the Spooler configuration, and FASTPX25 must be configured as the print process responsible for this device. Spooler device configuration is described in Spooler Configuration Considerations for FASTPX25 on page 6-9. Spooler FASTP Network Print Processes Manual — 427528-006 6 - 5...
NUA to the SVC. When an NUA is configured using the X25AM subdevice, the same number is always called (that is, no SVC sharing is performed). For example: SCF ASSUME SU $X25A.#P2 ABORT ALTER, DESTADDR "456172698" START Spooler FASTP Network Print Processes Manual — 427528-006 6 - 6...
Using SVC sharing can provide a degree of security against problems in lines between the HP host and the X.25 network. By specifying SVCs from different lines in the same list, FASTPX25 can print even if an entire X.25 line is down.
Associate each device name (that is, the device name designated for an X25 printer) with the appropriate FASTPX25 print process and specify the appropriate Spooler device attributes for each device using the Spoolcom DEV command. Spooler FASTP Network Print Processes Manual — 427528-006 6 - 8...
X25AM subdevice. For example, if an X25AM subdevice is named $X25A.#PRINT and the subdevice will be used by only one printer, the Spooler device name must be specified as: $X25A.#PRINT Spooler FASTP Network Print Processes Manual — 427528-006 6 - 9...
Table 2-3, Spooler Device Attributes and Their Effect on FASTP Network Printers, on page 2-7. Table 6-1 lists the Spooler device attributes that have special considerations for FASTPX25 and describes their effect on X.25 printers. Spooler FASTP Network Print Processes Manual — 427528-006 6 - 10...
DEV: device-name X25 Call failed to NUA address, Err: nnnnn DEV: device-name Using SVC svc for Job nnnn These messages are in addition to reporting the error to the Spooler supervisor. Spooler FASTP Network Print Processes Manual — 427528-006 6 - 11...
SVCLISTs to be specified. These lists can then be referenced by name in the DEVICE entries. The use and syntax of the MACRO entry is described in Using MACRO Entries on page 6-16. Spooler FASTP Network Print Processes Manual — 427528-006 6 - 12...
DESTADDR for the X25AM subdevice is ignored. This attribute should always be used when implementing SVC sharing. This attribute should not be used if the X25AM SU is configured to use a Permanent Virtual Circuit (PVC). Spooler FASTP Network Print Processes Manual — 427528-006 6 - 13...
Page 170
FASTPX25 print process resides. From 1 to 8 trace files can be defined. Tracing is discussed in Section 8, Troubleshooting and Using the Trace Facility. Spooler FASTP Network Print Processes Manual — 427528-006 6 - 14...
Page 171
PADs that do not clear the call when printers go not ready for long periods. By default, FASTPX25 uses a 10-minute timeout value for I/O completion. The timeout value specified can be up to 31 bits in size. Spooler FASTP Network Print Processes Manual — 427528-006 6 - 15...
1 and 256 X.25 SVCs. Each SVC must be separated by at least one space and the list must be completed with a semicolon (;). For example: MACRO LISTA SVCLIST = $X25B.#S1 $X25B.#S2 $X25C.#S1 $X25C.#S2; Spooler FASTP Network Print Processes Manual — 427528-006 6 - 16...
Note. For the remainder of this section, 4050 refers to all Xerox printer types unless otherwise indicated. Spooler FASTP Network Print Processes Manual — 427528-006 7 - 1...
TLAM or PAM I/O process. #name is a port name such as #XEROX. TYPE must be ETHERNET. ADDRESS must be %H0600; this is the defined address for XNS traffic. DELIVERYMODE must be parallel. Spooler FASTP Network Print Processes Manual — 427528-006 7 - 3...
To use a Xerox 4050 printer with FASTPXNS, the printer must have the Host Interface Processor (HIP) version 3.5 software installed, and the HIP Option Specification file (HIP.LIB) must be modified so that HIP can correctly receive print jobs from the HP NonStop system.
Page 179
Example 7-1 refers to a default JSL file which HIP uses to process print jobs. Example 7-2 contains a sample JSL file (TENET.JSL) that could be used by HIP: Spooler FASTP Network Print Processes Manual — 427528-006 7 - 5...
The creation of a FASTCNFG file is discussed in general terms in Configuring a FASTCNFG File on page 2-17. FASTCNFG DEVICE attributes for XNS printers are discussed in FASTCNFG DEVICE Configuration For FASTPXNS on page 7-11. Spooler FASTP Network Print Processes Manual — 427528-006 7 - 7...
For example, two Xerox printers on one LAN might be configured as: DEV $LAN1.#XEROX.P1 } DEV $LAN1.#XEROX.P2 whereas a single printer on one LAN might be configured as: DEV $LAN2.#XEROX Spooler FASTP Network Print Processes Manual — 427528-006 7 - 8...
Recommended setting for initial installation. If bit 2 is not set, FASTPXNS reports Xerox status messages only if the status is likely to affect the subsequent delivery of the job. Spooler FASTP Network Print Processes Manual — 427528-006 7 - 9...
Page 184
The data is first stored on disc at the printer. The Spooler job completes when all of the data has been stored on disc. The printer starts printing a job after the first few pages have been received. Spooler FASTP Network Print Processes Manual — 427528-006 7 - 10...
(%2000) of the PARM attribute using the Spoolcom DEV command. Note. If the HP host and Xerox printer are connected to different LAN segments and XNS routers (rather than bridges) are used to link the segments, then the source network (SNETWORK), destination network (DNETWORK), and router address (ROUTER) attributes are required, and must be configured.
Page 186
If specified, the destination network (DNETWORK), and router address (ROUTER) must also be configured. SNETWORK is expressed in hexadecimal notation. If XNS routers are not being used, the SNETWORK specification is not used. Spooler FASTP Network Print Processes Manual — 427528-006 7 - 12...
Trailer pages. The default JDL name used is TENET. For further details about the use of this attribute, see the description of the JSL File on page 7-5. Spooler FASTP Network Print Processes Manual — 427528-006 7 - 13...
Page 188
If no response is received after the configured RETRIES value, FASTPXNS places the device offline with error 104. Example 7-3 on page 7-15 shows a FASTCNFG file for a FASTPXNS print process. Spooler FASTP Network Print Processes Manual — 427528-006 7 - 14...
Spooler device to be placed offline with error 104. Unfortunately, FASTPXNS cannot detect the reason the Xerox controller is not responding — it only knows that the controller is not responding and not why. Spooler FASTP Network Print Processes Manual — 427528-006 7 - 15...
Clearinghouse and set time functions. If you encounter this type of problem, verify that the following three files are installed on the Xerox system drive: Spooler FASTP Network Print Processes Manual — 427528-006 7 - 16...
Full Spooler is full. Always FASTPXNS informs the Spooler supervisor that the device is not ready. Unknown FASTPPXNS Always FASTPXNS attempts to deliver job. could not ascertain status. Spooler FASTP Network Print Processes Manual — 427528-006 7 - 17...
Print command only works if the device is configured to print banners in the scope of any FONT jobs (DEV PARM 15 = true), or if DEV is configured with HEADER OFF. Spooler FASTP Network Print Processes Manual — 427528-006 7 - 19...
Emit the current minute as MM. Emit the current hour as HH. Emit the current day as 1st, 2nd, and so on. Emit the current day as DD. Emit the current month as text. Spooler FASTP Network Print Processes Manual — 427528-006 7 - 21...
Page 196
(255). Two consecutive bytes of 255 tell FASTPXNS that this is not a token but a single byte of 255 that should be emitted. Spooler FASTP Network Print Processes Manual — 427528-006 7 - 22...
Messages Where to Find Information About XNS Error Messages XNS error messages generated by HP products and other vendors LAN components are standardized. For information about these messages, consult the vendor documentation and textbooks available to the general public. Spooler FASTP Network Print Processes Manual — 427528-006...
Check the values you configured for the following Spoolcom commands: PRINT FONT FASTCNFG values Check the values you configured for the following FASTCNFG entries: HOSTS Spooler FASTP Network Print Processes Manual — 427528-006 8 - 1...
Page 200
The results of the following Spoolcom command: DEV $device, STATUS DETAIL The results of the following Spoolcom command: PRINT $device, STATUS DETAIL Spooler FASTP Network Print Processes Manual — 427528-006 8 - 2...
There are two types of shadow trace files. The original, entry-sequenced format, and a new unstructured format. An entry-sequenced trace file has the following characteristics: Is supported by all the FASTP network print processes, including FASTPTCP Spooler FASTP Network Print Processes Manual — 427528-006 8 - 3...
To create an entry-sequenced shadow trace file, enter the following FUP command: FUP CREATE $volume.subvolume.filename, TYPE E, REC 4000, EXT (n,n) where: $volume.subvolume.file specifies the name to be assigned to the shadow trace file. Spooler FASTP Network Print Processes Manual — 427528-006 8 - 4...
Guardian file used for trace output. If the file name is not fully qualified, the volume and subvolume default to the volume and subvolume Spooler FASTP Network Print Processes Manual — 427528-006 8 - 5...
Setting this bit allows shadow trace information for multiple jobs to accumulate in the shadow file. For configuration details, see PRINT PARM Attribute on page 3-10. Note that extending shadow trace files can, potentially, result in very large shadow files. Spooler FASTP Network Print Processes Manual — 427528-006 8 - 6...
For example, an OPEN command is not usually logged. Supervisor - DEV Status In Response received from supervisor process containing status for a device. Spooler FASTP Network Print Processes Manual — 427528-006 8 - 8...
To run the SHAP utility, enter the following command: RUN $dsv.ZTCPPRT.SHAP/IN shadow-file,OUT list-file/[CRLF,ASC, DATA=filename] where shadow-file specifies the name of the unstructured shadow output file produced by FASTPTCP. Spooler FASTP Network Print Processes Manual — 427528-006 8 - 9...
Page 208
In general, SHAP output is self-explanatory. Certain trace records are interpreted by SHAP. Because these records are primarily intended for support and development staff, the records are not documented in detail here. Spooler FASTP Network Print Processes Manual — 427528-006 8 - 10...
NONE NONE Norway NORSK7 NORSK8 Spain ESPANOL7 ESPANOL8 Sweden SVENSK7 SVENSK8 United Kingdom United States Note. NONE means no substitution is performed. Use NONE when binary transfers are required. Spooler FASTP Network Print Processes Manual — 427528-006 A - 1...
DEUTSCH Character Standard Spooler Substituted Substitution Character Character Paragraph A umlaut O umlaut U umlaut a umlaut o umlaut u umlaut Sharp S Spooler FASTP Network Print Processes Manual — 427528-006 A - 2...
Page 211
Umlaut NORSK Substituted Character Standard Spooler Character Substitution Character O slash A circle o slash a circle u umlaut Spooler FASTP Network Print Processes Manual — 427528-006 A - 3...
Page 212
A circle U umlaut e acute a umlaut o umlaut a circle u umlaut UK Substituted Character Standard Spooler Character Substitution Character English pound Spooler FASTP Network Print Processes Manual — 427528-006 A - 4...
FASTP network print process abends. If you cannot resolve the problem with the information in this section, you should contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 1...
Spooler and is generated only when bit 14 (%2) of PRINT PARM is set. Effect. None; this message is an informational message only. Recovery. Informational message only; no corrective action is needed. Spooler FASTP Network Print Processes Manual — 427528-006 B - 2...
Page 215
14 (%2) of PRINT PARM is set and is displayed only in EMS event format. Effect. None; this message is an informational message only. Recovery. Informational message only; no corrective action is needed. Spooler FASTP Network Print Processes Manual — 427528-006 B - 3...
Page 216
Cause. An unexpected internal error condition was detected within the FASTPTCP process. Effect. The FASTPTCP process abends and might create a ZZSAnnnn Saveabend file. Spooler FASTP Network Print Processes Manual — 427528-006 B - 4...
Page 217
If the error persists, or the cause of the error is unknown, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 5...
Page 218
If the error persists, or the cause of the error is unknown, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 6...
Page 219
If the error persists, or the cause of the error is unknown, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 7...
Page 220
If the error persists, or the cause of the error is unknown, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 8...
Page 221
If the error persists, or the cause of the error is unknown, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 9...
Page 222
If the error persists, or the cause of the error is unknown, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 10...
Page 223
If the error persists, or the cause of the error is unknown, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 11...
Page 224
If the error persists, or the cause of the error is unknown, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 12...
Page 225
Spooler mechanism as described in Configuring a FASTP Network Print Process on page 2-4. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 13...
Page 226
Spooler Programmer’s Guide. supervisor is the name of the Spooler supervisor process. Cause. The FASTPTCP process received an unexpected return code from the Spooler system procedure PRINTINIT. Spooler FASTP Network Print Processes Manual — 427528-006 B - 14...
Page 227
Effect. The status of the print job and the device is indeterminate. Recovery. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 15...
Page 228
Effect. The status of the print job and the device is indeterminate. Recovery. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 16...
Page 229
Effect. No printing occurs, the Spooler job is requeued, and the Spooler device is placed offline. Recovery. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 17...
Page 230
Recovery. Varies based on the user conversion routine. Consult the Guardian Procedure Calls Reference Manual for details. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 18...
Page 231
Recovery. Varies based on the user conversion routine. Consult the Guardian Procedure Calls Reference Manual for details. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 19...
Page 232
Recovery. Varies based on the user conversion routine. Consult the Guardian Procedure Calls Reference Manual for details. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 20...
Page 233
Errors and Messages Manual for explanations of file-system errors. Cause. The FASTPTCP process could not open the Spooler Collector data file to read the print job data. Effect. The device is placed offline. Spooler FASTP Network Print Processes Manual — 427528-006 B - 21...
Page 234
Recovery. Try reducing the number of devices configured for the FASTPTCP process (using the Spoolcom DEV command). If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 22...
Page 235
Effect. The Spooler job is requeued, and the Spooler device is placed offline. Recovery. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 23...
Page 236
Spooler job to be held, but the device can continue to print other jobs. Recovery. Ensure that the DEV CHARMAP parameter is set correctly. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 24...
Page 237
Effect. The FASTPTCP process uses the SETMODE 144 value in place of the value specified by the CHARMAP parameter. Recovery. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 25...
Page 238
Effect. The string is truncated to twenty bytes. Recovery. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 26...
Page 239
This message warns the operator that duplicate pages might be produced. Recovery. Informational message only; no corrective action is needed. Spooler FASTP Network Print Processes Manual — 427528-006 B - 27...
Page 240
Recovery. Verify that the Spooler is properly configured and is running. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 28...
Page 241
Recovery. Verify that the Spooler is properly configured and is running. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 29...
Page 242
Cause. The specified shadow trace file cannot be opened. Effect. Shadow tracing is not performed. Recovery. Purge the shadow trace file and ensure that Safeguard permits access to the shadow file. Spooler FASTP Network Print Processes Manual — 427528-006 B - 30...
Page 243
Cause. A shadow trace file was created. Effect. None; this message is an informational message only. Recovery. Informational message only; no corrective action is needed. Spooler FASTP Network Print Processes Manual — 427528-006 B - 31...
Page 244
Recovery. Reduce the complexity of CONTROLBUF 103 calls in the print and/or font job. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 32...
Page 245
See the Guardian Procedure Errors and Messages Manual for explanations of file-system errors. Cause. A position error occurred while processing a CONTROLBUF 130 request. Effect. The CONTROLBUF 130 request is ignored. Spooler FASTP Network Print Processes Manual — 427528-006 B - 33...
Page 246
CONTROLBUF 130 request. Cause. A CONTROLBUF 13O request was improperly formatted. Effect. The CONTROLBUF 130 request is ignored. Recovery. Correct the data in the CONTROLBUF 130 request. Spooler FASTP Network Print Processes Manual — 427528-006 B - 34...
Page 247
FASTCNFG File on page 2-17. If necessary, run FASTKCUT to generate the FASTKCON file, and restart the Spooler device. (Depending on the device configuration, the device might restart automatically.) Spooler FASTP Network Print Processes Manual — 427528-006 B - 35...
Page 248
Effect. No printing occurs, the Spooler job is requeued, and the Spooler device is placed offline with error 66. Recovery. Restart the Spooler device. (Depending on the device configuration, the device might restart automatically.) Spooler FASTP Network Print Processes Manual — 427528-006 B - 36...
Page 249
2 (%20000) of PRINT PARM is used. Effect. None; this message is an informational message only. It does not affect job printing. Recovery. Informational message only; no corrective action is needed. Spooler FASTP Network Print Processes Manual — 427528-006 B - 37...
Page 250
2 (%20000) of PRINT PARM is used. Effect. None; this message is an informational message only. It does not affect job printing. Recovery. Informational message only; no corrective action is needed. Spooler FASTP Network Print Processes Manual — 427528-006 B - 38...
Page 251
This event is generated only when bit 14 (%2) of PRINT PARM is set, and is displayed only in EMS event format. Effect. None; this message is an informational message only. Spooler FASTP Network Print Processes Manual — 427528-006 B - 39...
Page 252
Data was received other than a normal Do Timing Mark response. One common cause is a printer that is sending XON or XOFF characters when the AWAN or terminal server Spooler FASTP Network Print Processes Manual — 427528-006 B - 40...
Page 253
Effect. Refer to the description of the other LPD message that appears with this message. Recovery. Refer to the description of the other LPD message that appears with this message. Spooler FASTP Network Print Processes Manual — 427528-006 B - 41...
Page 254
HP JetDirect printer. Cause. This message applies to HP JetDirect printers only. The SMNP Get-Response returned the status text specified for printer-status, and the FASTPTCP process does not recognize this status. The FASTPTCP process has an internal list of the exact text returned from the printer.
Page 255
TEMPFILE specifies a complete file name, either use a unique file name for each device, change TEMPFILE to specify only a disk volume name, or completely omit the TEMPFILE parameter. Verify that Safeguard permits access to the specified TEMPFILE. Spooler FASTP Network Print Processes Manual — 427528-006 B - 43...
Page 256
TEMPFILE specifies a complete file name, either use a unique file name for each device, change TEMPFILE to specify only a disk volume name, or completely omit the TEMPFILE parameter. Verify that Safeguard permits access to the specified TEMPFILE. Spooler FASTP Network Print Processes Manual — 427528-006 B - 44...
Page 257
TEMPFILE specifies a complete file name, either use a unique file name for each device, change TEMPFILE to specify only a disk volume name, or completely omit the TEMPFILE parameter. Verify that Safeguard permits access to the specified TEMPFILE. Spooler FASTP Network Print Processes Manual — 427528-006 B - 45...
Page 258
TEMPFILE specifies a complete file name, either use a unique file name for each device, change TEMPFILE to specify only a disk volume name, or completely omit the TEMPFILE parameter. Verify that Safeguard permits access to the specified TEMPFILE. Spooler FASTP Network Print Processes Manual — 427528-006 B - 46...
Page 259
Effect. The Spooler job is terminated and requeued, and the Spooler device is placed offline. Recovery. Try a reset of the Lexmark device. Spooler FASTP Network Print Processes Manual — 427528-006 B - 47...
Page 260
Spooler device name. error-number is the socket error that occurred. See the TCP/IP and IPX/SPX Programming Manual for explanations of socket errors. operation is a text description of the socket operation. Spooler FASTP Network Print Processes Manual — 427528-006 B - 48...
Page 261
The ADDRESS parameter matches the IP address of the remote device. An operational network path to the device exists. The device is online and properly configured. Spooler FASTP Network Print Processes Manual — 427528-006 B - 49...
Page 262
For error 48, adjust the file security or restart the Spooler from another user ID. After the configuration file access is corrected, restart the Spooler device. (Depending on the device configuration, the device might restart automatically.) Spooler FASTP Network Print Processes Manual — 427528-006 B - 50...
Page 263
For error 48, adjust the file security or restart the Spooler from another user ID. After the configuration file access is corrected, restart the Spooler device. (Depending on the device configuration, the device might restart automatically.) Spooler FASTP Network Print Processes Manual — 427528-006 B - 51...
Page 264
See the Guardian Procedure Errors and Messages Manual for explanations of file-system errors. cnfg-file is the name of the FASTCNFG or FASTKCON file. Spooler FASTP Network Print Processes Manual — 427528-006 B - 52...
Page 265
FASTKCON, but the POLLTYPE record contains an error. Effect. The print job is requeued. Recovery. Correct the error in FASTCNFG, and then use FASTKCUT to update FASTKCON. Spooler FASTP Network Print Processes Manual — 427528-006 B - 53...
Page 266
Effect. For additional information, refer to the documentation from the third-party software provider. Recovery. For additional information, refer to the documentation from the third-party software provider. Spooler FASTP Network Print Processes Manual — 427528-006 B - 54...
Page 267
Correct the network error. Ensure that the device is online and is not out of paper. Restart the Spooler device. (Depending on the device configuration, the device might restart automatically.) Spooler FASTP Network Print Processes Manual — 427528-006 B - 55...
Page 268
Effect. The device is placed offline and the job is requeued. No printing occurs. Recovery. Change DEVTYPE to a legal setting (blank is commonly used) with the SPOOLCOM DEV command and restart the device. Spooler FASTP Network Print Processes Manual — 427528-006 B - 56...
Page 269
SHADOW trace file. Cause. SHADOW tracing was specified to an already existing SHADOW trace file. Effect. The trace file is extended with new trace data. Recovery. None, informational only. Spooler FASTP Network Print Processes Manual — 427528-006 B - 57...
Cause. This message applies to FASTPXNS only. FASTPXNS received an ABORT packet from the specified device during the bulk data transfer phase. As a result the bulk data transfer phase did not complete processing. Spooler FASTP Network Print Processes Manual — 427528-006 B - 58...
Page 271
As a result the bulk data transfer phase did not complete processing. The most likely cause of this error is if the Xerox HIP buffers become full while the job is being sent. Effect. The device is placed offline. Spooler FASTP Network Print Processes Manual — 427528-006 B - 59...
Page 272
See the Guardian Procedure Errors and Messages Manual for explanations of file-system errors. file-name is the shadow trace file name. Cause. The specified shadow trace file cannot be created. Spooler FASTP Network Print Processes Manual — 427528-006 B - 60...
Page 273
EXCLUSIVE attribute on the FASTCNFG file, see FASTCNFG File Alteration on page 2-19. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 61...
Page 274
Effect. The Spooler job is requeued, and the Spooler device is placed offline. Recovery. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 62...
Page 275
See the Guardian Procedure Errors and Messages Manual for explanations of file-system errors. Cause. The specified FASTCNFG or FASTKCON file could not be opened due to a file-system error. Spooler FASTP Network Print Processes Manual — 427528-006 B - 63...
Page 276
Recovery. If the wrong FASTCNFG or FASTKCON file is used, either correct the DEFINE statement and restart the Spooler or correct the FASTCNFG= parameter in the higher level FASTCNFG file. If a FASTCNFG file does not exist (error 11), create one. Spooler FASTP Network Print Processes Manual — 427528-006 B - 64...
Page 277
DEV: device-name Cannot OPEN Supervisor for Status, Err: file-err on supervisor-name proc-num is the process number (CPU, PIN) of the process. device-name is the Spooler device name. Spooler FASTP Network Print Processes Manual — 427528-006 B - 65...
Page 278
If a free SVC cannot be found, the device is placed offline. Recovery. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 66...
Page 279
DEV: device-name Cannot send to Supervisor for Status, Err: file-err on supervisor-name proc-num is the process number (CPU, PIN) of the process. device-name is the Spooler device name. Spooler FASTP Network Print Processes Manual — 427528-006 B - 67...
Page 280
The ADDRESS parameter matches the IP address of the remote device. An operational network path to the device exists. The device is online and properly configured. Spooler FASTP Network Print Processes Manual — 427528-006 B - 68...
Page 281
Cause. A shadow trace file was created. Effect. None; this message is an informational message only. Recovery. Informational message only; no corrective action is needed. Spooler FASTP Network Print Processes Manual — 427528-006 B - 69...
Page 282
FASTPX25 could not verify the CONTYPE was X25. Effect. The device is placed offline. Recovery. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 70...
Page 283
Effect. The device is placed offline. Recovery. Either change the device configuration so that it matches that of the actual device or specify another device name that actually is associated with an X25AM subdevice. Spooler FASTP Network Print Processes Manual — 427528-006 B - 71...
Page 284
(CPU, PIN) of the process. device-name is the Spooler device name. param-name is one of the attributes for FASTPNOV devices. cnfg-file is the name of the FASTCNFG file. Spooler FASTP Network Print Processes Manual — 427528-006 B - 72...
Page 285
Cause. This message applies to FASTPNOV and FASTPSMB only. The specified parameter was not found in the FASTCNFG file. Effect. No printing occurs, the Spooler job is requeued, and the Spooler device is placed offline. Spooler FASTP Network Print Processes Manual — 427528-006 B - 73...
Page 286
SNMP processing. Effect. The Spooler job is terminated and requeued, and the Spooler device is placed offline. Recovery. Try a reset of the Microplex device. Spooler FASTP Network Print Processes Manual — 427528-006 B - 74...
Page 287
Correct the network error. Ensure the device is online and is not out of paper. Restart the Spooler device. (Depending on the device configuration, the device might restart automatically.) Spooler FASTP Network Print Processes Manual — 427528-006 B - 75...
Page 288
SETMODE to the specified device. Effect. The device is placed offline. Recovery. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 76...
Page 289
WRITEX procedure being performed. The value is one of: For normal printer types Normal After device recovery Re-Issue For remote Spooler collector processes SPOOLSSTART Spooler FASTP Network Print Processes Manual — 427528-006 B - 77...
Page 290
Recovery. Verify that the FASTCNFG or FASTKCON file exists and has correct information. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 78...
Page 291
(CPU, PIN) of the process. device-name is the Spooler device name. file-err is the file-system error. See the Guardian Procedure Errors and Messages Manual for explanations of file-system errors. Spooler FASTP Network Print Processes Manual — 427528-006 B - 79...
Page 292
Instead of a message specifically indicating the device is not found, this message indicates an error in the specified param-name. The param-name value displayed varies by product as follows: FASTPTCP Param: ADDRESS Spooler FASTP Network Print Processes Manual — 427528-006 B - 80...
Page 293
Effect. No printing occurs, the Spooler job is requeued, and the Spooler device is placed offline with error 66. Recovery. Restart the Spooler device. (Depending on the device configuration, the device might restart automatically.) Spooler FASTP Network Print Processes Manual — 427528-006 B - 81...
Page 294
Cause. This message applies to FASTPXNS only. FASTPXNS could not decode a buffer received from TLAM. Effect. The buffer is discarded and FASTPXNS waits for the next TLAM response. Spooler FASTP Network Print Processes Manual — 427528-006 B - 82...
Page 295
EXCLUSIVE attribute on the FASTCNFG file, see FASTCNFG File Alteration on page 2-19. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 83...
Page 296
FASTPTCP. The timeout interval (TIMEOUT) value specified for a device in the specified FASTCNFG file is not a valid value. Effect. The Spooler device is placed offline; the FASTP network print process continues processing other print jobs. Spooler FASTP Network Print Processes Manual — 427528-006 B - 84...
Page 297
DEV: device-name Illegal XNS Courier Params n proc-num is the process number (CPU, PIN) of the process. device-name is the Spooler device name. is the invalid Courier parameter. Spooler FASTP Network Print Processes Manual — 427528-006 B - 85...
Page 298
DEV: device-name Internal Error %nnnnnn From Format SDU header proc-num is the process number (CPU, PIN) of the process. device-name is the Spooler device name. %nnnnnn is the octal code for the internal error. Spooler FASTP Network Print Processes Manual — 427528-006 B - 86...
Page 299
(CPU, PIN) of the process. device-name is the Spooler device name. hex-data is a hexadecimal display of some of the data received from the printer. Spooler FASTP Network Print Processes Manual — 427528-006 B - 87...
Page 300
(CPU, PIN) of the process. device-name is the Spooler device name. param-name is the name of the parameter. The value is one of: PRINTERADDRESS ROUTER Address SNETWORK DNETWORK DEPTH TIMEOUT HOLDOFF CONTIMEOUT CONRETRIES Spooler FASTP Network Print Processes Manual — 427528-006 B - 88...
Page 301
(CPU, PIN) of the process. device-name is the Spooler device name. Cause. The specified device name was configured as CONTYPE=X25, but the subdevice associated with the device name is not an X25AM subdevice. Spooler FASTP Network Print Processes Manual — 427528-006 B - 89...
Page 302
(CPU, PIN) of the FASTPTCP process. device-name is the Spooler device name. job-num is the job number. file-name is the name of the Spooler Collector data file. Spooler FASTP Network Print Processes Manual — 427528-006 B - 90...
Page 303
FASTP network print process attempts to reprint the job from a point in the job that it knows printed correctly. This message warns the operator that duplicate pages might be produced as a result. Recovery. Informational message only; no corrective action is needed. Spooler FASTP Network Print Processes Manual — 427528-006 B - 91...
Page 304
FASTCNFG file name. Cause. The FASTCNFG file for this device contained an SVCMACRO attribute but FASTPX25 could not locate the specified MACRO entry. Effect. The device is placed offline. Spooler FASTP Network Print Processes Manual — 427528-006 B - 92...
Page 305
DEV: device-name MBCS Substitute Shift to DBCS string too long, Job: job-num proc-num is the process number (CPU, PIN) of the process. device-name is the Spooler device name. Spooler FASTP Network Print Processes Manual — 427528-006 B - 93...
Page 306
8-1. proc-num DEV: device-name MBCS Translation Error, Job: job-num, Err: %nnnnnn proc-num is the process number (CPU, PIN) of the process. device-name is the Spooler device name. Spooler FASTP Network Print Processes Manual — 427528-006 B - 94...
Page 307
7-11, or add a device record to FASTCNFG as described in Configuring a FASTCNFG File on page 2-17. Restart the Spooler device. (Depending on the device configuration, the device might restart automatically.) Spooler FASTP Network Print Processes Manual — 427528-006 B - 95...
Page 308
Cause. The NetWare file server print queue is servicing a job. Effect. FASTPNOV continues attempting to log on to the NetWare file server for the number of retries and the retry interval specified in the FASTCNFG file. Spooler FASTP Network Print Processes Manual — 427528-006 B - 96...
Page 309
Recovery. See the Guardian Procedure Errors and Messages Manual for recovery actions for file-system errors. NetWare Error=Hex 00210006, Hex 00210096, Hex 002100FC, or Hex 002100FF Cause. An error occurred after the job completed successfully. Spooler FASTP Network Print Processes Manual — 427528-006 B - 97...
Page 310
Recovery. Increase the time limit allowed for a user on the NetWare file server. Restart the Spooler device. (Depending on the device configuration, the device might restart automatically.) NetWare Error=Hex 000900C5 Spooler FASTP Network Print Processes Manual — 427528-006 B - 98...
Page 311
Cause. There is no response from the NetWare file server. Effect. FASTPNOV continues attempting to communicate with the NetWare file server for the number of retries and the retry interval specified in the FASTCNFG file. Spooler FASTP Network Print Processes Manual — 427528-006 B - 99...
Page 312
Recovery. Remove unused programs from the NetWare file server or consider adding additional memory to it. NetWare Error=Hex 000700F0 or Hex 000700FC Cause. An illegal wildcard value or nonexistent object has been specified for a NetWare file server print queue. Spooler FASTP Network Print Processes Manual — 427528-006 B - 100...
Page 313
Cause. The user does not have the appropriate security to access the NetWare file server print queue. Effect. FASTPNOV puts any devices representing print queues for the NetWare file server offline. Spooler FASTP Network Print Processes Manual — 427528-006 B - 101...
Page 314
Spooler device. (Depending on the device configuration, the device might restart automatically.) NetWare Error=Hex 002100FC Cause. There is no such print queue. Effect. FASTPNOV puts any devices representing print queues for the NetWare file server offline. Spooler FASTP Network Print Processes Manual — 427528-006 B - 102...
Page 315
Effect. The effect depends on which file-system error occurred. See the Guardian Procedure Errors and Messages Manual for explanations of file-system errors. Recovery. See the Guardian Procedure Errors and Messages Manual for recovery actions for file-system errors. Spooler FASTP Network Print Processes Manual — 427528-006 B - 103...
Page 316
(Depending on the device configuration, the device might restart automatically.) proc-num DEV: device-name OPEN Error: file-err on scp-name proc-num is the process number (CPU, PIN) of the process. device-name is the Spooler device name. Spooler FASTP Network Print Processes Manual — 427528-006 B - 104...
Page 317
If your installation doesn’t use $ZNET, check that you have added a DEFINE=SCP statement before running the Spooler supervisor. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 105...
Page 318
(CPU, PIN) of the process. device-name is the Spooler device name. %nnnnnn is the ACK value FASTPXNS received. %mmmmmm is the ACK value FASTPXNS expected to receive. Spooler FASTP Network Print Processes Manual — 427528-006 B - 106...
Page 319
(CPU, PIN) of the process. device-name is the Spooler device name. file-err is the file-system error. See the Guardian Procedure Errors and Messages Manual for explanations of file-system errors. Spooler FASTP Network Print Processes Manual — 427528-006 B - 107...
Page 320
DEV: device-name SMB operation Err: file-err NCB:ncb-retcode SMB:smb-class.smb-status ncb-name proc-num is the process number (CPU, PIN) of the process. device-name is the Spooler device name. operation is one of the following SMB operations: Spooler FASTP Network Print Processes Manual — 427528-006 B - 108...
Page 321
File-system errors: Refer to the Guardian Procedure Errors and Messages Manual for explanations of file-system errors. NetBIOS errors: Refer to the Multilan/TLAM Programming Manual (D-series only), your LAN vendor documentation, or other NetBIOS documentation. Spooler FASTP Network Print Processes Manual — 427528-006 B - 109...
Page 322
FASTPTCP does not recognize this status. FASTPTCP has an internal list of the exact text returned from the printer. As HP or third-party emulators release new printers, network cards, or firmware updates, sometimes a new status message is added or the text of an existing message is slightly altered.
Page 323
Spooler Supervisor. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. For FASTPX25, the cause, effect, and recovery are as follows: Spooler FASTP Network Print Processes Manual — 427528-006 B - 111...
Page 324
SPI interface to TLAM through the SCP process (usually $ZNET). Effect. The device is placed offline. Recovery. To correct the problem: Ensure that the SCP process is running correctly. Spooler FASTP Network Print Processes Manual — 427528-006 B - 112...
Page 325
SSINIT procedure. This message can be generated by FASTPXNS or FASTPX25 only. For FASTPXNS, the cause, effect, and recovery are as follows: Spooler FASTP Network Print Processes Manual — 427528-006 B - 113...
Page 326
If your installation doesn’t use $ZNET, check that you have added a DEFINE=SCP statement before running the Spooler Supervisor. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 114...
Page 327
Spooler Supervisor. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. For FASTPX25, the cause, effect, and recovery are as follows: Spooler FASTP Network Print Processes Manual — 427528-006 B - 115...
Page 328
DEV PARM 2 is set on in Spoolcom, FASTPXNS reports the Xerox spooler status regardless. Effect. See Table 7-2 on page 7-17. Recovery. See Table 7-2 on page 7-17. Spooler FASTP Network Print Processes Manual — 427528-006 B - 116...
Page 329
Effect. The device is placed offline. Recovery. Delete or correct the invalid item in the SVCLIST and restart the device. (Depending on the device configuration, the device might restart automatically.) Spooler FASTP Network Print Processes Manual — 427528-006 B - 117...
Page 330
Cause. This message applies to FASTPX25 only. The SVCs specified for this device brings the total number of unique SVCs known to this FASTPX25 process to more than 256. Effect. The device is placed offline. Spooler FASTP Network Print Processes Manual — 427528-006 B - 118...
Page 331
FASTCNFG file name. Cause. This message applies to FASTPX25 only. The list of SVCs specified for the device contains more than 256 entries. Effect. The device is placed offline. Spooler FASTP Network Print Processes Manual — 427528-006 B - 119...
Page 332
(CPU, PIN) of the process. device-name is the Spooler device name. temp-name is the name of the temporary disk file, either from the FASTCNFG parameter TEMPFILE or a default name. Spooler FASTP Network Print Processes Manual — 427528-006 B - 120...
Page 333
DEV: device-name Time Out Waiting For Connection - R: retries T: time proc-num is the process number (CPU, PIN) of the process. device-name is the Spooler device name. Spooler FASTP Network Print Processes Manual — 427528-006 B - 121...
Page 334
Sequence Packet transmission. Effect. Error 104 is returned to the Spooler supervisor. Recovery. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 122...
Page 335
(CPU, PIN) of the process. device-name is the Spooler device name. %nnnnnn is the unexpected answer type that was received. Typical values that might appear are 1 (Reject) and 2 (Abort). Spooler FASTP Network Print Processes Manual — 427528-006 B - 123...
Page 336
Troubleshooting and Reporting Problems on page 8-1. proc-num DEV: device-name Using SVC svc for Job job-num proc-num is the process number (CPU, PIN) of the process. device-name is the Spooler device name. Spooler FASTP Network Print Processes Manual — 427528-006 B - 124...
Page 337
Effect. No printing occurs, the Spooler job is requeued, and the Spooler device is placed offline. Recovery. Correct the parameter, and restart the Spooler device. (Depending on the device configuration, the device might restart automatically.) Spooler FASTP Network Print Processes Manual — 427528-006 B - 125...
Page 338
If your installation doesn’t use $ZNET, check that you have added a DEFINE=SCP statement before running the Spooler Supervisor. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 126...
Page 339
Effect. The device is placed offline. A subsequent message identifies the operation being performed. Recovery. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 127...
Page 340
RECOVERY attribute in the FASTCNFG file. The default value is NORMAL, which results in the behavior described above. If you set this attribute to REPRINT, FASTPX25 returns to the first page of the job when printing is resumed. Spooler FASTP Network Print Processes Manual — 427528-006 B - 128...
Page 341
(CPU, PIN) of the process. device-name is the Spooler device name. is the contents of the cause field in the X.25 clear request packet. Spooler FASTP Network Print Processes Manual — 427528-006 B - 129...
Page 342
Spoolcom DEV RETRY value. As a default, FASTPXNS attempts to reprint the job at the last known correctly printed page. As a result, FASTPX25 might reprint certain pages. Spooler FASTP Network Print Processes Manual — 427528-006 B - 130...
Page 343
(Depending on the device configuration, the device might restart automatically.) proc-num DEV: device-name XNS Close Connection Error n proc-num is the process number (CPU, PIN) of the process. device-name is the Spooler device name. Spooler FASTP Network Print Processes Manual — 427528-006 B - 131...
Page 344
Cause. This message applies to FASTPXNS only. FASTPXNS did not get a response to the printing protocol request for job status at the end of job. Effect. FASTPXNS attempts to close the XNS connection. Spooler FASTP Network Print Processes Manual — 427528-006 B - 132...
Page 345
XNS Courier Get Printer Status RPC, which determines printer readiness. Effect. The device is placed offline. Recovery. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 133...
Page 346
Spooler Programmer’s Guide. spooler-operation identifies the Spooler operation where the error occurred. The value is one of: PRINTCOMPLETE on supervisor PRINTINFO PRINTINIT on supervisor PRINTREADCOMMAND PRINTSTART Spooler FASTP Network Print Processes Manual — 427528-006 B - 134...
Page 347
[: param1 param2] are optional parameter definitions that further describe the internal error. Cause. An unexpected internal error condition was detected within the FASTP network print process. Spooler FASTP Network Print Processes Manual — 427528-006 B - 135...
Page 348
Spooler supervisor process. Cause. Because FASTP network print processes are started automatically by the Spooler supervisor using the name configured with Spoolcom PRINT, this message Spooler FASTP Network Print Processes Manual — 427528-006 B - 136...
Page 349
Spooler PRINTREAD procedure. Effect. The device is placed offline. Recovery. If the error persists, contact your service provider as described in Troubleshooting and Reporting Problems on page 8-1. Spooler FASTP Network Print Processes Manual — 427528-006 B - 137...
Page 350
EMS Messages FASTP EMS 512 Text Messages Spooler FASTP Network Print Processes Manual — 427528-006 B - 138...
Page 351
France for FASTPNOV 5-11 Germany DELETE 2-40 Norway FORM selection 2-37 for all FASTP network printers 2-40 Spain for FASTPNOV 5-11 Sweden HOLD 2-40 United Kingdom HOLDAFTER United States Spooler FASTP Network Print Processes Manual — 427528-006 Index - 1...
Page 352
FASTP network printers 2-40 CONTROLBUF 100 7-21 for FASTPNOV 5-11 CONTROLBUF 101 2-28 JOB subcommand CONTROLBUF 103 2-29 for all FASTP network printers 2-38 CONTROLBUF 109 2-30 Spooler FASTP Network Print Processes Manual — 427528-006 Index - 2...
Page 353
FASTPTCP (HP JetDirect DEVTYPE connection) 3-26 DRAIN for FASTPTCP (Lexmark ENDFF connection) 3-32 EXCLUSIVE for FASTPTCP (Microplex special considerations 2-19 connection) 3-34 FIFO for FASTPTCP (serial printer connection) 3-21 for FASTPNOV Spooler FASTP Network Print Processes Manual — 427528-006 Index - 3...
Page 354
PostScript printing 2-37, 3-55 for FASTPNOV enabling tracing for FASTPX25 ENDFF attribute for FASTPXNS ENDPORT attribute 3-38 general format error messages device subtype FASTKCUT 3-52 for FASTPNOV NetBIOS 4-15 Spooler FASTP Network Print Processes Manual — 427528-006 Index - 4...
Page 355
2-19 DEFAULT keyword 3-41 generating from a FASTKCON DEVICE attributes file 3-48, 3-52 defined 2-24 HOSTS keyword 3-14 for FASTPNOV in network environment for FASTPSMB keywords 2-22 Spooler FASTP Network Print Processes Manual — 427528-006 Index - 5...
Page 357
JOBNAME attribute 3-39 for all FASTPTCP devices 3-17 KEEPALIVEattribute 3-18 for LPD connection 3-36 LPDBIND attribute 3-38 BANNERCLASS attribute 3-39 NOTIMINGMARK attribute, for serial BLOCK attribute 3-18 printer connection 3-21 Spooler FASTP Network Print Processes Manual — 427528-006 Index - 7...
Page 358
Spooler DEV attributes 3-11 considerations subtype, device 3-12 SUBS140 attribute 6-15 TCP/IP-A attribute SVCLIST attribute 6-15 for all FASTPTCP devices 3-19 SVCMACRO attribute 6-15 for Lexmark connection 3-33 Spooler FASTP Network Print Processes Manual — 427528-006 Index - 8...
Page 359
Font script file HOLDOFF attribute 7-13 example for an LPD connection 3-56 installation requirements example using CONTROLBUF installation tasks 2-28 installation troubleshooting 7-15 example using CONTROLBUF 2-29 JSL file 7-4, Spooler FASTP Network Print Processes Manual — 427528-006 Index - 9...
Page 360
Supervisor-Job Status Out HOLDAFTER subcommand types of BATCH subcommand IDLETIMEOUT attribute 3-18 for all FASTP network printers 2-40 indent count 3-54 for FASPNOV 5-11 initialization job limitation 2-41 JOB subcommand 2-39 Spooler FASTP Network Print Processes Manual — 427528-006 Index - 10...
Page 361
FASTP network printers 2-38 FASTPX25 for FASTPNOV 5-10 line continuation and FASTCNFG file 2-21, 2-22 HOLD 2-38 LINK subcommand, BATCH HOLDAFTER 2-39 subcommand 2-40 Spooler FASTP Network Print Processes Manual — 427528-006 Index - 11...
Page 362
ONLINEMODE attribute 3-28, 3-34 national-use characters OPEN command of Spoolcom NetBIOS opening a Spooler subsystem 2-14 error messages 4-15 Operator Hold (NetWare print job attributes) 5-15 protocol ORIGINATOR attribute 4-10 NetWare Spooler FASTP Network Print Processes Manual — 427528-006 Index - 12...
Page 363
3-24 POLLNUM attribute for FASTPTCP (HP JetDirect QUEUE attribute connection) 3-27 queue name replacement 3-53 for FASTPTCP (Lexmark QUEUENAME attribute 3-36 connection) 3-33 for FASTPTCP (TTAP connection) 3-25 Spooler FASTP Network Print Processes Manual — 427528-006 Index - 13...
Page 364
FASTCNFG file 2-19 for FASTPTCP (Lexmark connection) 3-33 security for a FASTKCON file 3-50 select character set 2-37 for FASTPTCP (serial printer connection) 3-22 SELPRI subcommand Spooler FASTP Network Print Processes Manual — 427528-006 Index - 14...
Page 365
FASTCNFG DEV command file 2-21, 2-22 JOB subcommand considerations Start Print command, alternative 7-21 for FASTP network printers 2-38 START subcommand Spooler FASTP Network Print Processes Manual — 427528-006 Index - 15...
Page 366
SUSPEND attribute 2-10 facility 1-5, SVCLIST attribute 6-15 file SVCMACRO attribute 6-15 characteristics switched virtual circuit (SVC) considerations configuring in FASTCNFG file for FASTPX25 6-6, creating data record Spooler FASTP Network Print Processes Manual — 427528-006 Index - 16...
Page 367
TROFFR file name 3-54 FASTPX25 TROFFS file name 3-54 PROTOCOL attribute TRUNC attribute 2-10 RECSIZE attribute TTAP printer connection, DEVICE REMOTENET attribute attributes 3-24 TYPE attribute 4-14 Spooler FASTP Network Print Processes Manual — 427528-006 Index - 17...