2
Preparation
1) Setup of driving condition from deceleration to after stop by main power-off (Pr5.07)
Sequence at main
power-off (Pr5.0)
Setup value of Pr5.07
0
1
2
3
4
5
6
7
8
9
Torque limit value at emergency stop will be that of Pr5.11 (Setup of torque at emergency stop)
when the setup value is 8 or 9.
2) Setup of driving condition from deceleration to after stop by Servo-OFF (Pr5.06)
Sequence at main
Servo-OFF (Pr5.06)
Setup value of Pr5.06
0
1
2
3
4
5
6
7
8
9
Torque limit value at emergency stop will be that of Pr5.11 (Setup of torque at emergency stop)
when the setup value is 8 or 9.
12. Dynamic Brake
Condition setting chart
During deceleration
Free-run
Free-run
Free-run
Free-run
Emergency stop
Emergency stop
During deceleration
Free-run
Free-run
Free-run
Free-run
Emergency stop
Emergency stop
Driving condition
After stalling
D B
D B
D B
D B
Free-run
Free-run
D B
D B
D B
D B
Free-run
Free-run
D B
Free-run
Driving condition
After stalling
D B
D B
D B
D B
Free-run
Free-run
D B
D B
D B
D B
Free-run
Free-run
D B
Free-run
Contents of
deviation
counter
Clear
Clear
Clear
Clear
Hold
Hold
Hold
Hold
Clear
Clear
Contents of
deviation
counter
Clear
Clear
Clear
Clear
Hold
Hold
Hold
Hold
Clear
Clear
2-37
1
2
3
4
5
6
7