Panasonic MINAS A5-series Operating Instructions Manual page 321

Minas a5-series ac servo motor and driver
Table of Contents

Advertisement

7
Supplement
Following alarm will be displayed when making the front panel to alarm execution mode
of monitor mode.
• Press
• Kinds of alarm
alarm
Alarm
No.
A0
Overload protection
A1
Over-regeneration alarm
A2
Battery alarm
A3
Fan alarm
Encoder communication
A4
alarm
A5
Encoder overheat alarm
A6
Oscillation detection alarm
A7
Lifetime detection alarm
A8
External scale error alarm
External scale
A9
communication alarm
*1 Alarms can be cleared by using the alarm clear. Because the all existing alarms are kept cleared while the alarm
clear input (A-CLR) is kept ON, be sure to turn it OFF during normal operation. Either 1-10s or∞ can be selected
by using user parameter.
Exception: Battery alarm is fixed at ∞ because it is latched by the encoder.
Because the end of life alarm means that the life expectancy cannot be extended, the alarm is set at ∞.
How to Clear the Battery Alarm
Replace the battery for absolute encoder when battery alarm occurs according to P.276,
"How to Replace the Battery". After replacement, clear the battery alarm in the following
3 methods.
(a) "Connector X4" Connecting Alarm clear input (A-CLR) to COM– for more than 120ms.
(b) Executing the alarm clear function in auxiliary function mode by using the front panel.
(c) Click the "Battery warning" Clear button, after select the "Absolute encoder" tab in the
monitor display window by using the PANATERM (option).
Related page
• P.2-75 "Alarm Clear Screen"
• P.3-30 "Inputs and outputs on connector X4"
• P.7-26 "Outline of Setup Support Software, "PANATERM""
2. Absolute system
Display of Battery Alarm
....... No alarm condition
...... Highest priority alarm
Alarm number
to scroll alarm conditions.
Load factor is 85% or more the protection level.
Regenerative load factor is 85% or more the
protection level.
Battery voltage is 3.2 V or lower.
Fan has stopped for 1 sec.
The number of successive encoder communication
errors exceeds the specified value.
The encoder detects overheat alarm.
Oscillation or vibration is detected.
The life expectancy of capacity or fan becomes
shorter than the specified time.
The feedback scale detects the alarm.
The number of successive feedback scale
communication errors exceeds the specified value.
Content
1
2
3
Latched
time
*1
1 to 10s or ∞
4
10s or ∞
Fixed at ∞
1 to 10s or ∞
1 to 10s or ∞
1 to 10s or ∞
1 to 10s or ∞
5
Fixed at ∞
1 to 10s or ∞
1 to 10s or ∞
6
7
7-25