4. Inputs and outputs on connector X4
Input Signal and Pin No.
Title of
Gain switching input
signal
GAIN
Symbol
• Select 1st or 2nd gain.
Title of
Torque limit switching input
signal
TL-SEL
Symbol
• Select 1st or 2nd torque limit.
Pr5.21
0
1
2
3
4
5
6
*1
To specify the torque limit value by an analog input, refer to Pr5.21 "Analog torque limit
function".
• Setup of rate of change after torque limit switchover
When applying Pr5.21 "Torque limit selection" = 3, changing rate of torque (slope) after
selecting new torque limit can be changed.
When changing from the 1st torque limit to 2nd torque limit, the changing rate (slope) set at
Pr5.23 "Torque limit selection setup 1" is applied; after changing from the 2nd torque limit
to 1st torque limit, the changing rate (slope) set at Pr5.24 "Torque limit selection setup 2" is
applied. The sign of the changing rate is automatically selected by the driver according to the
difference in value between the 1st and 2nd torque limit.
If Pr5.23 "Torque limit selection setup 1" and Pr5.24 "Torque limit selection setup 2" are set to 0,
switchover is instantaneous.
Torque limit selection input
(TL-SEL)
1st torque limit
(Pr0.13)
2nd torque limit
(Pr5.22)
Caution
When the 1st torque limit (Pr0.13) and 2nd torque limit (Pr5.22) are changed from the front
panel or through communication, the changing rate setup is ignored and the new torque limit
value is immediately and directly applied. That is, changing rate setting is effective only when
the selection is made by using the torque limit select input (TL-SEL).
3-40
Default assignment
Default assignment
Torque limit
Torque limit
switching input
switching setup
(TL-SEL)
(Pr5.23, Pr5.24)
OFF
ON
OFF
ON
control mode
SI4
control mode
Positive direction
Torque limit
Pr0.13
Valid
Pr0.13
Pr5.25
Torque limit selection setup 1 (Pr5.23)
Torque limit selection setup 2 (Pr 5.24)
Related
P
S
T
SI 3-30
I/F circuit
page
Related
P
S
T
SI 3-30
I/F circuit
page
Negative direction
Torque limit
* 1
Analog input
Pr0.13
Pr5.22
Pr0.13
Pr5.22
Analog input
* 1
Pr5.22
Pr5.26
F