1. Outline of mode
Position Control Mode
(4) Pulse regeneration function
The information on the amount of movement can be sent to the host controller in the
form of A- and B-phase pulses from the servo driver. When the output source is the
encoder, Z-phase signal is output once per motor revolution; or if the feedback scale,
the signal is output at absolute zero position. The output resolution, B-phase logic and
output source (encoder or feedback scale) can be set with parameters.
• Relevant parameters
Parameter
No.
Pr0.11
Pr0.12
Pr5.03
Pr5.33
Pr6.20
Pr6.21
Pr6.22
Note
For details of these parameters, refer to P.4-8, 9, 42, 49 and 54 "Details of parameter".
(5) Deviation counter clear function
The deviation counter clear input (CL) clears the counts of positional deviation counter
at the position control to 0.
• Relevant parameters
Parameter
No.
Pr5.17
Note
For details of these parameters, refer to P.4-46 "Details of parameter".
3-4
Title
Range
Output pulse counts
per one motor
1 to 262144
revolution
Reversal of pulse
output logic
Denominator of pulse
0 to 262144
output division
Pulse regenerative
output limit setup
Z-phase setup of
0 to 400
external scale
Serial absolute
external scale Z phase
268435456
setup
A, B phase external
scale pulse output
method selection
Title
Range
Counter clear input
mode
Unit
You can set up the output pulse counts per
P/r
one motor revolution for each OA and OB
with the Pr0.11 setup.
You can set up the B-phase logic and
the output source of the pulse output.
With this parameter, you can reverse the
0 to 3
—
phase relation between the A-phase pulse
and the B-phase pulse by reversing the
B-phase logic.
For application where the number of
pulses per revolution is not an integer,
this parameter can be set to a value other
—
than 0, and the dividing ratio can be set by
setting numerator of division to Pr0.11 and
denominator of division to Pr5.03.
Enable/disable detection of Err28.0 Pulse
0 to 1
—
regenerative limit protection.
Set up the Z phase regenerative width of
μs
feedback scale in unit of time.
Full-closed control using serial absolute
feedback scale. When outputting pulses by
0 to
using the feedback scale as the source of
pulse
the output, set the Z phase output interval
in units of A phase output pulses of the
feedback scale (before multiplied by 4).
Select the pulse regeneration method of A,
0 to 1
—
B and Z parallel feedback scale.
You can set up the clearing conditions of the
0 to 4
counter clear input signal.
Function
Function