15. How to Use the Front Panel
Auxiliary Function Mode (EXECUTION display)
4) Clearing of Absolute Encoder
You can clear the multi-turn data of the absolute encoder.
SELECTION display
• Press
to call for
EXECUTION display.
• After clearing of absolute encoder finishes, return to SELECTION display, referring to struc-
Note
ture of each mode (P.2-54).
• Keep pressing
(SET button)
when you execute Clearing of Absolute Encoder.
Clearing of
absolute encoder
completes
EXECUTION display
until the display changes to
"
" increases while keep
pressing
(for approx. 5sec)
as the right fig. shows.
Clearing of absolute encoder starts
Clearing
finishes
Error occurs
(
When non-applicable
encoder is connected
1
2
3
4
)
5
6
7
2-79