Panasonic MINAS A5-series Operating Instructions Manual page 299

Minas a5-series ac servo motor and driver
Table of Contents

Advertisement

7
Supplement
Safety input/output signal
For list of connector pin numbers, refer to P.2-22,
Signal
Safety
input 1
Safety
input 2
Safety input 1 or 2 enables STO to operate within 5 ms, causing motor output torque to
turn off.
• Safety equipment self-diagnosis L pulse
Caution
Safety output signal from the safety controller and safety sensor may include L pulse for
self-diagnosis.
To prevent the L pulse from mis-triggering STO function, the safety input circuit has
built-in filter that removes the self-diagnosis L pulse.
Therefore, if the off period of safety input signal less than 1 ms, the safety input circuit
does not detect this "off" event.
To validate this "off" period, turn off the input signal for more than 5 ms.
Safety input
signal
Servo driver
Operate
1. Safety function
Input & output signals
Symbol
Pin No.
• Input 1 that triggers STO function. This input turns
SF1+
4
off the upper arm drive signal of power transistor.
• When using the function, connect this pin in a way
so that the photocoupler of this input circuit turns off
SF1−
3
to activate STO function.
• Input 2 that triggers STO function. This input turns
SF2+
6
off the lower arm drive signal of power transistor.
• When using the function, connect this pin in a way
so that the photocoupler of this input circuit turns off
SF2−
5
to activate STO function.
L pulse for self-diagnosis
1 ms or shorter
Contents
5 ms or more
5 ms or shorter
STO state
1
2
Control
mode
Compatible
all control
mode
3
4
5
6
7
7-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents