8. Messages
None.
KAPL01079-W
The intermittent error monitoring function cannot be set up
because automatic failback is disabled.
Details
The intermittent error monitoring function cannot be set up because automatic
failbacks are disabled.
Action
Enable automatic failbacks, and then re-execute.
KAPL01080-W
The error monitoring interval and the number of times that the
error is to occur conflict with the automatic failback checking
interval.
Details
An intermittent error cannot be detected by using the values specified for the
following: the checking interval for automatic failbacks, the error-monitoring
interval, and the number of times the error needs to occur.
Action
Set the intermittent error-monitoring interval to a value that is equal to or greater
than (automatic-failback-checking-interval x
number-of-times-error-is-to-occur-for-intermittent-error-monitoring).
KAPL01081-E
The license key file is invalid. File name = aa...aa
Details
The format of the license key file is invalid.
aa...aa:
/var/tmp/hdlm_license
Action
Save the correct license key file in the designated, and then re-execute.
/var/tmp/hdlm_license
KAPL01082-E
There is no installable license key in the license key file. File
name = aa...aa
Details
There is no useable license key for HDLM in the license key file.
aa...aa:
/var/tmp/hdlm_license