VLAN Translation Settings

VLAN translation translates the VLAN ID carried in the data packets it receives from private networks into those used
in the Service Providers
To view this window, click L2 Features > QinQ > VLAN Translation Settings, as shown below:
The fields that can be configured are described below:
Parameter
Unit
From Port / To Port
CVID (1, 5-7)
Action
SVID (1-4094)
Priority
This is used to decide if the ingress packet is c-tagged. Inner tag TPID is per system
configurable.
Select a unit to be configured.
A consecutive group of ports that are part of the VLAN configuration starting with the
selected port.
The user can choose between UNI or NNI role.
UNI – To select a user-network interface which specifies that communication between the
specified user and a specified network will occur.
NNI – To select a network-to-network interface specifies that communication between two
specified networks will occur.
Use the drop-down menu to enable or disable missdrop. If missdrop is enabled, the packet
that does not match any VLAN translation rule on the UNI port will be dropped. If disabled,
then the packet will be assigned the S-VLAN tag based on the VLAN classification rule of
the received port.
The Outer TPID is used for learning and switching packets. The Outer TPID constructs and
inserts the outer tag into the packet based on the VLAN ID and Inner Priority.
This is the priority given to the inner tag that is copied to the outer tag if this setting is
enabled.
Deselect the Disabled check box and enter an inner tag for the packet to use.
network.
Figure 4-27 VLAN Translation Settings window
Description
Select a unit to be configured.
A consecutive group of ports that are part of the VLAN configuration starting with the
selected port.
The customer VLAN ID List to which the tagged packets will be added.
Specify for SPVID packets to be added or replaced.
This configures the VLAN to join the Service Providers VLAN as a tagged member.
Select a priority for the VLAN ranging from 0 to 7. With 7 having the highest priority.