Page 3
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Table of Contents Intended Readers .................................... v Typographical Conventions .................................... v Notes, Notices, and Cautions ................................. v Safety Instructions..................................vi Safety Cautions ......................................vi General Precautions for Rack-Mountable Products............................vii Protecting Against Electrostatic Discharge ..............................
Page 5
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Introduction ....................................24 Login to Web Manager ....................................24 Web-based User Interface ..................................... 25 Web Pages ........................................26 Technical Specifications ..........................27 Cable Lengths ..............................34 Glossary ................................35 Warranties and Tech Support Information ....................
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Intended Readers The DES-3528/DES-3552 Switch Series Hardware Installation Guide contains information for setup and management of the Switch. This manual is intended for network managers familiar with network management concepts and terminology.
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Safety Instructions Use the following safety guidelines to ensure your own personal safety and to help protect your system from potential damage. Throughout this document, the caution icon ( ) is used to indicate cautions and precautions that you need to review and follow.
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual • To help prevent electric shock, plug the system and peripheral power cables into properly grounded electrical outlets. These cables are equipped with three-prong plugs to help ensure proper grounding. Do not use adapter plugs or remove the grounding prong from a cable.
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual NOTE: A qualified electrician must perform all connections to DC power and to safety grounds. All electrical wiring must comply with applicable local, regional or national codes and practices. CAUTION: Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor.
The following manual describes the installation, maintenance and configurations concerning the xStack DES-3528, DES-3528DC, DES-3528P, DES-3552 and DES-3552P switches. Please take note that if this device was purchased outside of Europe, certain cosmetic differences between the actual switch and images in this document will be apparent to the reader, such as the faceplate and the manual cover.
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual routers, switches and other networking devices. The dual speed ports use standard twisted-pair cabling and are ideal for segmenting networks into small, connected sub networks for superior performance. Each 10/100 port can support up to 200 Mbps of throughput in full-duplex mode.
DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Ports The following table lists the relative ports that are present within each switch: Device Features DES-3528 DES-3528DC DES-3528P DES-3552 DES-3552P 10/100BASE-T Ports 24 Ports 24 Ports 24 Ports...
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual NOTE: For customers interested in D-View, D-Link Corporation's proprietary SNMP management software, go to the D-Link Website (www.dlink.com) and download the software and manual. Front-Panel Components DES-3528 •...
Figure 1- 5. Front Panel View of the DES-3552P switch LED Indicators The Switch supports LED indicators for Power, Console, RPS, Master (on DES-3528P and DES-3552P, this LED is for MS) and Port LEDs. The following shows the LED indicators for the DES-3528/DES-3552 switch series along with an explanation of each indicator.
Page 15
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Figure 1- 9. LED Indicators on DES-3528P switch Figure 1- 10. LED Indicators on DES-3552P switch...
Page 16
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual LED indicators for DES-3528/DES-3528DC/DES-3552/DES-3528P/DES-3552P Location LED Indicative Color Status Description Solid Light Power On Power Green Light off Power Off Solid Light Console on Console Green Blinking POST is in progress.
Page 17
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Power device may receive power from Light off power source 802.3af/802.3at PD is found. When there is a secure 1000Mbps Solid Green connection (or link) at any of the ports. When there is reception or transmission Blinking Green (i.e.
RPS. Figure 1- 11. Rear panel view of the DES-3528 The DES-3528P rear panel contains ports 27 and 28, (1000BASE-T), an AC power connector, and an outlet for an optional external RPS. Figure 1- 12. Rear panel view of the DES-3528P The DES-3552 rear panel contains ports 51 and 52, (1000BASE-T), RS-232 DCE Diagnostic port (console port), an AC power connector, and an outlet for an optional external RPS.
Figure 1- 16. Side panels of the DES-3528/DES-3528DC The right-hand side panel of the DES-3552 and DES-3528P Switches contain two system fans and ventilation along the entire right side. The left hand panel includes a heat vent. The system fans are used to dissipate heat. Do not block these openings on either side of the Switch.
Page 20
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Figure 1- 19. Inserting the SFP modules into the DES-3528/DES-3528P/DES-3528DC/DES-3552/DES-3552P Figure 1-20. Installing the SFP Module...
Install the Switch on a sturdy, level surface that can support at least 6.6 lbs (3 kg) of weight for DES- 3528/DES-3528DC, at least 13.2 lbs (6 kg) of weight for DES-3552/DES-3528P, at least 15.4 lbs (7 kg) of weight for DES-3552P. Do not place heavy objects on the Switch.
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Installing the Switch without the Rack When installing the Switch on a desktop or shelf, the rubber feet included with the Switch should first be attached. Attach these cushioning feet on the bottom at each corner of the device. Allow enough ventilation space between the Switch and any other objects in the vicinity.
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Mounting the Switch in a Standard 19" Rack CAUTION: Installing systems in a rack without the front and side stabilizers installed could cause the rack to tip over, potentially resulting in bodily injury under certain circumstances. Therefore, always install the stabilizers before installing components in the rack.
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Connecting DC Power to the DES-3528DC Follow the instructions below to connect the DC power supply of the DES-3528DC to the DC power source. Figure 2- 4. Power connections attached to contacts after assembly 1.
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Section 3 Connecting the Switch Switch to End Node Switch to Hub or Switch Connecting To Network Backbone or Server NOTE: All 24/48 high-performance NWay Ethernet ports can support both MDI-II and MDI-X connections.
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Figure 3- 2. The Switch connected to a normal (non-Uplink) port on a hub or switch using a straight or crossover cable Connecting To Network Backbone or Server The two SFP combo ports are ideal for linking to a network backbone or server.
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Section 4 Introduction to Switch Management Management Options Web-based Management Interface SNMP-Based Management Connecting the Console Port (RS-232 DCE) First Time Connecting to the Switch Password Protection SNMP Settings IP Address Assignment Management Options...
Page 28
Upon the initial connection, there is no user name or password and therefore just press “enter” twice to access the command line interface. DES-3528 Fast Ethernet Switch Command Line Interface Firmware: Build 2.00.B036 Copyright(C) 2009 D-Link Corporation. All rights reserved. Username: Figure 4- 1. Initial screen after first connection...
3528:5# shown below: There is no initial username or password. Leave the Username and Password fields blank. DES-3528 Fast Ethernet Switch Command Line Interface Firmware: Build 2.00.B036 Copyright(C) 2009 D-Link Corporation. All rights reserved. Username: PassWord: DES-3528:5# Figure 4- 2. Command Prompt NOTE: The first user automatically gets Administrator level privileges.
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual NOTE: Passwords are case sensitive. User names and passwords can be up to 15 characters in length. The sample below illustrates a successful creation of a new administrator-level account with the user name "newmanager".
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Using SNMP v.3 individual users or groups of SNMP managers can be allowed to perform or be restricted from performing specific SNMP management functions. The functions allowed or restricted are defined using the Object Identifier (OID) associated with a specific MIB.
Page 32
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual The Switch's MAC address can also be found from the Web management program on the Switch Information (Basic Settings) window on the Configuration menu. The IP address for the Switch must be set before it can be managed with the Web-based manager. The Switch IP address can be automatically set using BOOTP or DHCP protocols, in which case the actual address assigned to the Switch must be known.
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Section 5 Web-based Switch Configuration Introduction Login to Web Manager Web-based User Interface Web Pages Introduction All software functions of the Switch can be managed, configured and monitored via the embedded web-based (HTML) interface.
Area 1 Select the folder or window to be displayed. The folder icons can be opened to display the hyper- linked window buttons and subfolders contained within them. Click the D-Link logo to go to the D- Link website. Area 2 Presents a graphical near real-time image of the front panel of the Switch.
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Web Pages When you connect to the management mode of the Switch with a web browser, a login window is displayed. Enter a user name and password to access the Switch's management mode. Below is a list and description of the main folders available in the web interface: Configuration –...
UTP Cat.5, Cat. 5 Enhanced for 100BASE-TX UTP Cat.3, 4, 5 for 10BASE-T EIA/TIA-568 100-ohm screened twisted-pair (STP)(100m) Number of Ports DES-3528/DES-3528DC/DES-3528P 24 x 10/100Base-T Ports, 2 x 1000Base-T/SFP Combo Ports, 2 x 1000Base-T ports DES-3552/DES-3552P 48 x 10/100Mbps T Ports, 2 x 1000Base-T/SFP Combo Ports, 2 x...
Page 38
DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual A3: 0˚ to 50˚ C DES-3528DC: 0˚ to 45˚ C DES-3528P: 0˚ to 50˚ C DES-3552: A1: 0˚ to 45˚ C A2: 0˚ to 50˚ C DES-3552P: 0˚ to 50˚ C Storage Temperature -40 - 70°C...
Page 39
Detailed Description Feature Wire speed on all FE/GE ports Full-wire speed (full-duplex) operation on all FE/GE ports Forwarding Mode Store and Forward Switching Capacity DES-3528/DES-3528DC/DES-3528P 12.8Gbps DES-3552/DES-3552P 17.6Gbps 64 Byte system packet forwarding DES-3528/DES-3528DC/DES-3528P rate 9.5 million 64-byte packets per second.
Page 40
IEEE 802.3x Flow Control support for Full-Duplex mode, back pressure when Half-Duplex mode, and Head-of-line blocking prevention PoE Features DES-3528P and DES-3552P Feature Detailed Description DES-3528P: Port 1-24; DES-3552P: Port 1-48 PoE Capable Ports DES-3528P Port 1~8: 30W Port 9~24: 15.4W...
Page 41
Transmit+ & Power+ Transmit- & Power+ Positive Vport 8. All the PoE ports can work with all D-Link 802.3af capable devices 9. All the PoE ports can work with all non-802.3af capable D-Link AP, IP Cam and IP phone via DWL-P50...
Page 42
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual FE Port Pin Assignment for Data Pairs: (MDI-X) PIN# Signal Description Receive+ Positive Receive signal Receive- Negation Receive signal Transmit+ Positive Transmit signal Transmit- Negation Transmit signal FE Port PSE Pinout Assignment for Power Pairs: (alternative A MDI-X) PIN# Signal...
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Appendix B Cable Lengths Use the following table to as a guide for the maximum cable lengths. Standard Media Type Maximum Distance 1000BASE-LX, Single-mode fiber module 10km 1000BASE-SX, Multi-mode fiber module 550m 1000BASE-LHX, Single-mode fiber module...
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual Appendix C Glossary 1000BASE-SX: A short laser wavelength on multimode fiber optic cable for a maximum length of 2000 meters 1000BASE-LX: A long wavelength for a "long haul" fiber optic cable for a maximum length of 10 kilometers 1000BASE-T: 1000Mbps Ethernet implementation over Category 5E cable.
Page 45
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual half duplex: A system that allows packets to be transmitted and received, but not at the same time. Contrast with full duplex. IP address: Internet Protocol address. A unique identifier for a device attached to a network using TCP/IP. The address is written as four octets separated with full-stops (periods), and is made up of a network section, an optional subnet section and a host section.
Page 46
® xStack DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual UDP - User Datagram Protocol: An Internet standard protocol that allows an application program on one device to send a datagram to an application program on another device. VLAN - Virtual LAN: A group of location- and topology-independent devices that communicate as if they are on a common physical LAN.
The customer must submit with the product as part of the claim a written description of the Hardware defect or Software nonconformance in sufficient detail to allow D-Link to confirm the same, along with proof of purchase of the product (such as a copy of the dated purchase invoice for the product).
Page 48
D-Link Corporation/D-Link Systems, Inc., as stipulated by the United States Copyright Act of 1976 and any amendments thereto. Contents are subject to change without prior notice. Copyright 2009 by D-Link Corporation/D-Link Systems, Inc.
Product Registration Register your D-Link product online at http://support.dlink.com/register/ Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights.
You can find software updates and user documentation on the D- Link website. D-Link provides free technical support for customers within the United States and within Canada for the duration of the service period, and warranty confirmation service, during the warranty period on this product.
Technical Support United Kingdom (Mon-Fri) Home Wireless/Broadband 0871 873 3000 (9.00am–06.00pm, Sat 10.00am-02.00pm) Managed, Smart, & Wireless Switches, or Firewalls 0871 873 0909 (09.00am – 05.30pm) (BT 10ppm, other carriers may vary.) Ireland (Mon-Fri) All Products 1890 886 899 (09.00am-06.00pm, Sat 10.00am-02.00pm) €0.05ppm peak, €0.045ppm off peak Times Internet http://www.dlink.co.uk...
0.12 € la minute : Du lundi au vendredi de 9h à 19h Assistance technique D-Link sur internet : http://www.dlink.fr Asistencia Técnica Asistencia Técnica Telefónica de D-Link: +34 902 30 45 45 0,067 €/min De Lunes a Viernes de 9:00 a 19:00 http://www.dlink.es Supporto tecnico Supporto Tecnico dal lunedì...
Page 53
Pomoc techniczna Telefoniczna pomoc techniczna firmy D-Link: 0 801 022 021 Pomoc techniczna firmy D-Link świadczona przez Internet: URL: http://www.dlink.pl e-mail: serwis@dlink.pl Technická podpora Web: http://www.dlink.cz/suppport/ E-mail: support@dlink.cz Telefon: 225 281 553 Telefonická podpora je v provozu: PO- PÁ od 09.00 do 17.00 Pevná...
Page 54
Teknistä tukea asiakkaille Suomessa: Arkisin klo. 9 - 21 numerosta : 06001 5557 Internetin kautta : http://www.dlink.fi Teknisk Support D-Link Teknisk Support via telefon: 0900-100 77 00 Vardagar 08.00-20.00 D-Link Teknisk Support via Internet: http://www.dlink.se Assistência Técnica Assistência Técnica da D-Link na Internet: http://www.dlink.pt...
Page 55
D-Link - ovo spletno stran www.dlink.eu www.dlink.biz/sl Suport tehnica Vă mulţumim pentru alegerea produselor D-Link. Pentru mai multe informaţii, suport şi manuale ale produselor vă rugăm să vizitaţi site-ul D-Link www.dlink.eu www.dlink.ro...
Page 56
Technical Support You can find software updates and user documentation on the D-Link website. Tech Support for customers in Australia: Tel: 1300-766-868 24/7 Technical Support Web: http://www.dlink.com.au E-mail: support@dlink.com.au India: Tel: 1800-233-0000 (MTNL & BSNL Toll Free) +91-832-2885700 (GSM, CDMA & Others) Web: www.dlink.co.in...
Page 57
Technical Support You can find software updates and user documentation on the D-Link website. Tech Support for customers in Egypt: Tel: +202-2919035, +202-2919047 Sunday to Thursday 9:00am to 5:00pm Web: http://support.dlink-me.com E-mail: support.eg@dlink-me.com Iran: Tel: +98-21-88880918,19 Saturday to Thursday 9:00am to 5:00pm Web: http://support.dlink-me.com...
Page 58
Техническая поддержка Обновления программного обеспечения и документация доступны на Интернет-сайте D-Link. D-Link предоставляет бесплатную поддержку для клиентов в течение гарантийного срока. Клиенты могут обратиться в группу технической поддержки D-Link по телефону или через Интернет. Техническая поддержка D-Link: +7(495) 744-00-99 Техническая поддержка через Интернет...
Page 59
SOPORTE TÉCNICO Usted puede encontrar actualizaciones de softwares o firmwares y documentación para usuarios a través de nuestro sitio www.dlinkla.com SOPORTE TÉCNICO PARA USUARIOS EN LATINO AMERICA Soporte técnico a través de los siguientes teléfonos de D-Link PAIS NUMERO HORARIO...
Page 60
Você pode encontrar atualizações de software e documentação de usuário no site da D-Link Brasil. A D-Link fornece suporte técnico gratuito para clientes no Brasil durante o período de vigência da garantia deste produto. Suporte Técnico para clientes no Brasil: Website para suporte: www.dlink.com.br/suporte...
Page 62
Dukungan Teknis Update perangkat lunak dan dokumentasi pengguna dapat diperoleh pada situs web D-Link. Dukungan Teknis untuk pelanggan: Dukungan Teknis D-Link melalui telepon: Tel: +62-21-5731610 Dukungan Teknis D-Link melalui Internet: Email : support@dlink.co.id Website : http://support.dlink.co.id...
Page 63
Technical Support この度は弊社製品をお買い上げいただき、誠にありがとうご ざいます。 下記弊社 Web サイトからユーザ登録及び新製品登録を 行っていただくと、ダウンロードサービスにて サポート情報、ファームウェア、ユーザマニュアルを ダウンロードすることができます。 ディーリンクジャパン Web サイト URL:http://www.dlink-jp.com...
8. What category best describes your company? Aerospace Engineering Education Finance Hospital Legal Insurance/Real Estate Manufacturing Retail/Chain store/Wholesale Government Transportation/Utilities/Communication System house/company Other________________________________ 9. Would you recommend your D-Link product to a friend? Don't know yet 10.Your comments on this product? __________________________________________________________________________________________ __________________________________________________________________________________________...
Need help?
Do you have a question about the xStack DES-3528P and is the answer not in the manual?