D-Link DES-3528 - xStack Switch - Stackable Reference Manual page 138

Layer 2 managed stackable fast ethernet switch, web ui reference guide
Hide thumbs Also See for DES-3528 - xStack Switch - Stackable:
Table of Contents

Advertisement

xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch Web UI Reference Guide
The fields that can be configured are described below:
Parameter
Ring Status
West Port
East Port
RPL Port
RPL Owner
Protected VLAN(s) (e.g.:
4-6)
Ring MEL (0-7)
Holdoff Time (0-10000)
Guard Time (10-2000)
WTR Time (5-12)
Click the Edit button to configure the information within the table.
Click the Apply button to implement the changes made.
Click the <<Back button to go back to the previous page.
After clicking the
Sub-Ring Information
Figure 4-82 ERPS Settings - Detail Information window
Description
Tick the check box and use the drop-down menu to enable or disable the ring status.
Tick the check box to configure the information. Use the Unit drop-down menu to
select a unit to be configured, and then use the next drop-down menu to specify the
port as the west ring port, or select Virtual Channel to specify the west port on virtual
channel.
Tick the check box to configure the information. Use the Unit drop-down menu to
select a unit to be configured, and then use the next drop-down menu to specify the
port as the east ring port, or select Virtual Channel to specify the east port on virtual
channel.
Tick the check box and use the drop-down menu to select one of the R-APS VLAN
ring ports as the RPL port. Select None to have no RPL port.
Tick the check box and use the drop-down menu to enable or disable the device as an
RPL owner node.
Tick the check box, select the Add radio button and enter the VLAN ID to add the
VLAN into protected VLAN group.
Tick the check box, select the Delete radio button and enter the VLAN ID to remove
the VLAN into protected VLAN group.
Tick the check box and enter the ring MEL of the R-APS function from 0 to 7. The
default is 1.
Tick the check box and enter the holdoff time of the R-APS function from 0 to 10000
milliseconds. The default is 0 milliseconds.
Tick the check box and enter the guard time of the R-APS function from 10 to 2000
milliseconds. The default is 500 milliseconds.
Tick the check box and enter the WTR time of the R-APS function from 5 to 12
minutes. The default is 5 minutes.
link, the following page will appear: