Diagnostic Dbm Configuration Options - Paradyne COMSPHERE 3610 Operator's Manual

Data service units
Hide thumbs Also See for COMSPHERE 3610:
Table of Contents

Advertisement

Diag Type: Disr
Next
NonD
Disr
Diagnostic Type . Defines the diagnostic interaction between the control and tributary DSUs in Backup mode.
It must be set consistently for all DSUs on the same circuit.
NonD —
Nondisruptive Diagnostics. An in-band secondary channel transport is derived to carry
diagnostics data between the control and the tributary DSUs. Nondisruptive diagnostics are
unavailable using the DMC protocol.
Disr
Disruptive Diagnostics. The same (primary) channel that carries user-transmitted data between
the control and the tributary DSUs also carries diagnostic data. This mode should be selected
for compatibility with earlier releases that use session-disruptive diagnostics.
Mixed —
This mode supports nondisruptive health and status updates. User-initiated commands are
sent disruptively. Mixed is unavailable using the DMC protocol and should only be selected in
single-port multipoint configurations.
None
No diagnostic communications with remote devices; only local diagnostics are allowed.
2nd Ch(bps): 400
Next
100
400
In-band Secondary Channel Diagnostic Transport Speed (in bps) . Determines the DBM's port speed when
NonD (nondisruptive diagnostics) is selected and there is no excess bandwidth available for in-band
secondary channel transport operation. (This configuration option only appears when DiagType = NonD.)
The selection entered here allocates DBM port bandwidth to the in-band secondary channel transport. For
example, both the DBM port speed and the backup line speed are 9.6 kbps, and the Diagnostic Type
entered is NonD and the In-band Secondary Channel Diagnostic Transport Speed entered is 400. The
resulting DBM port speed is 9.2 kbps. (Refer to the following list for valid diagnostic speeds.)
If the DBM Rate(Kbps) is equal to Port
Speed, or if the underspeed port speed
and sum of the TDM ports is equal to
the aggregate speed on the DBM:
1.2
2.0
2.4
4.0
4.8
7.2
8.4
9.6
12.0
14.4
16.8
18.0
19.2
28.8
32
38.4
48
56
64
3610-A2-GB91-90
Table 6-3
(1 of 2)

Diagnostic DBM Configuration Options

Mixed
None
Prev
800
1200
1600
Valid diagnostic speeds are:
100, 400
100, 400
100, 400, 800
100, 400, 800
100, 400, 800, 1200, 1600
100, 400, 800, 1200
100, 400, 1600
100, 400, 800, 1200, 1600
100, 400, 800, 1200
100, 400, 800, 1200, 1600
100, 400, 800, 1200
100, 400, 1200
100, 400, 800, 1200, 1600
100, 400, 800
100, 400, 800, 1600
100, 400, 800, 1200, 1600
100, 400, 800, 1200, 1600
100, 400, 800, 1600
100, 400, 800, 1600
July 1999
Prev
Configuration Options
6-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3611Comsphere 3600 series

Table of Contents