Changing External Leads; Reporting External Lead Changes To Nms; Lead States - Paradyne COMSPHERE 3610 Operator's Manual

Data service units
Hide thumbs Also See for COMSPHERE 3610:
Table of Contents

Advertisement

COMSPHERE 3600 Series Data Service Units
Press the
or
key to display the output leads
(A is Pin 12, B is Pin 13):
External Leads:
Out A:
F1
F2
Table 4-13 describes the meaning of the state of each
input or output lead.

Changing External Leads

The Change (Chang) selection allows you to change
the state of the two output leads (for example, change a
lead to signal a console operator or reset a remote
computer). Table 4-13 indicates the possible states of the
output leads.
Table 4-13

Lead States

Symbol
?
NOTES:
Input leads A and B:
Off (
) when voltage on lead is less than +.8V.
ON (
) when voltage on lead is more than
+2.2V.
Output leads are either ON or Off:
When output is set to Off (
to lead.
When output is set to ON (
to lead.
If addressing this function to a remote DSU, its
network address is required.
4-38
Out B:
F3
Meaning
Off (below text line)
ON (above text line)
Changing
Indicates an illegal value.
), –12V is applied
), +12V is applied
To change the output lead states, press the F2 key from
the External Leads submenu. The following appears:
OutA:
F1
On this display, the F1 key selection ( ) toggles the
display between (
The field where the cursor is positioned flashes in inverse
video. The
or
Out A and Out B fields.
After the leads are set, press the F2 key to save the
leads in the specified state.
OutA:
F1
Save Ext Leads:
Command Complete
F1

Reporting External Lead Changes to NMS

Changing the output leads from the DCP or NMS, or
changing the input leads, changes the DSU's health and
status message. If the DSU is polled by the NMS using
ADp, the 6800 Series NMS reports a change
configuration notification (CCN) event. The 6700 Series
NMS will also report a change configuration notice if
enabled. The NMS operator can then issue a CCN
Display command to determine what caused the event. If
the event was caused by the state in the external leads, the
operator can select Displ from the External Leads (ExtL)
branch to see the current states of the external leads. In
addition, if a positive voltage is detected in either one of
the input leads, an external leads alarm is also reported.
July 1999
OutB:
Save
F2
F3
) and (
) for one lead at a time.
key moves the cursor between the
OutB:
Save
F3
F2
F3
F2
3610-A2-GB91-90