Default Configuration Option Sets - Paradyne COMSPHERE 3610 Operator's Manual

Data service units
Hide thumbs Also See for COMSPHERE 3610:
Table of Contents

Advertisement

COMSPHERE 3600 Series Data Service Units
When Opts is selected, the following appears:
Load from:
Activ
Remt
F1
F2
Usr2
Usr3
FacC
The selections on this menu are configuration option
sets or libraries of configuration options stored in the
DSU's memory. Table 4-10 lists the Load from option
selections and their source.
Table 4-10

Default Configuration Option Sets

Menu
Selection
Configuration Options
Activ
The addressed DSUs currently
active options.
Remt
Options can be retrieved from a
selected tributary DSU; these
may be from the tributary's Activ,
Usr1, Usr2, or Usr3 set.
The selected option set can then
be displayed, edited, and saved
back to the same tributary,
another tributary, or the control
DSU.
Usr1
User-defined option sets.
Usr2
User-defined option sets.
1
Usr3
User-defined option sets, and
factory default settings for a
DBM-V, DBM-S, or DBM-D.
FacC
Factory default settings for a
control DSU.
FacT
Factory default settings for a
tributary DSU.
FacB
Factory default settings for a
central-site bridge.
1
If configuring a DBM-V, DBM-S, or DBM-D, do
not SAVE to Usr3.
4-30
Usr1
F3
FacT
FacB
Source Of
July 1999
If you select Activ, Usr1, Usr2, Usr3, FacC, or FacT
from the Load from menu, a complete set of
configuration option values is loaded into a working
buffer.
Usr1, Usr2, and Usr3 are storage areas for user-defined
configuration option sets. This feature allows the rapid
loading of an entire configuration option set, saving the
time required to change each individual configuration
option.
If you select Remt from the Load from menu, an
address is required. The remote ADp address selections
range from 1 to 255 (1 to 80 for DPII protocol). For a list
of allowable addresses, see the
Chapter 1.
When the configuration options are saved to a remote
device, they can be saved to all the remote devices by
selecting 192 (the Broadcast Address). If 192 is selected,
the configuration options changed are broadcast to the
entire network after the configuration options are saved.
When downloading configuration options, it is
recommended that the control and tributary DSUs have
the same firmware version, or that the control has the
highest version.
After you enter the tributary address, press F3 to
display the following submenu for a remote device:
Load from:
Activ
Usr1
F1
F2
Usr3
Each of the selections listed in
Remt) loads a complete set of configuration options into a
working buffer in the local DSU. Once the values are
loaded into the DSU, the Edit/Save submenu appears.
Edit/Save:
SAVE
DSU
F1
F2
DBM
Gen
Bckup
From this point, you will be editing and saving
configuration options. Refer to
configure your unit.
Addressing
section in
Usr2
F3
Table 4-10
(except for
Diag
F3
Chapter 6
to learn how to
3610-A2-GB91-90